{"product_id":"560361","title":"CPX-4AE-P-B2","description":"analogue module CPX-4AE-P-B2 Dimensions W x L x H=(* (including interlinking block), * 50 mm x 107 mm x 55 mm), No. of inputs=4, Diagnosis=(* - Limit value violation per channel, * - Parameterisation error, * - Sensor limit per channel), Parameters configuring=(* - Diagnosis delay per channel, * - Hysteresis per module, * - Unit of measurement, * - Measured value smoothing per channel, * - Diagnosis limit monitoring per channel, * - Diagnostics sensor limit per channel, * - Relative\/differential pressure measurement), Measured variable=4x relative pressure\/2x differential pressure\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(including interlinking block)50 mm x 107 mm x 55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of inputs\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnosis\u003c\/th\u003e\n\u003ctd\u003e'- Limit value violation per channel- Parameterisation error- Sensor limit per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameters configuring\u003c\/th\u003e\n\u003ctd\u003e'- Diagnosis delay per channel- Hysteresis per module- Unit of measurement- Measured value smoothing per channel- Diagnosis limit monitoring per channel- Diagnostics sensor limit per channel- Relative\/differential pressure measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured variable\u003c\/th\u003e\n\u003ctd\u003e4x relative pressure\/2x differential pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnit(s) that can be displayed\u003c\/th\u003e\n\u003ctd\u003ekPambarpsi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED displays\u003c\/th\u003e\n\u003ctd\u003e'- 1 Group diagnosis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal cycle time\u003c\/th\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating voltage range DC\u003c\/th\u003e\n\u003ctd\u003e18 ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at operating voltage\u003c\/th\u003e\n\u003ctd\u003eTypically 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air in accordance with ISO8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on operating and pilot medium\u003c\/th\u003e\n\u003ctd\u003eLubricated operation possible (subsequently required for further operation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48755572736155,"sku":"560361","price":771.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/560361-1.jpg?v=1781298937","url":"https:\/\/festopneumatics.com\/products\/560361","provider":"Festo Pneumatics","version":"1.0","type":"link"}