{"title":"Remote i o and network interface components","description":"\u003cp\u003eDistribute I\/O close to sensors and actuators with Festo remote I\/O and network interfaces. CPX-AP platforms, fieldbus modules, and AS-Interface components cut cable lengths and simplify machine expansion.\u003c\/p\u003e","products":[{"product_id":"8112476","title":"CPX-AP-A-EPL","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(installation dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eDirect mounting via through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e120g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eArbitrary, on H-rail: horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnd plate material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum, coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769639121051,"sku":"8112476","price":46.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8112476-1.jpg?v=1781463817"},{"product_id":"8112477","title":"CPX-AP-A-EPR","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(installation dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eDirect mounting via through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e116g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eArbitrary, on H-rail: horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnd plate material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum, coated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003ePU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769639153819,"sku":"8112477","price":46.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8112477-1.jpg?v=1781463819"},{"product_id":"8129109","title":"CPX-AP-A-8DI-M12-5P","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(incl. interlinking block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e87g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eAny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e30 m inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCover material\u003c\/th\u003e\n\u003ctd\u003ePBT-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-ring material\u003c\/th\u003e\n\u003ctd\u003eFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eDiagnostics per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnose per internal communication\u003c\/th\u003e\n\u003ctd\u003eCommunication error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e1byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel parameters\u003c\/th\u003e\n\u003ctd\u003eInput debounce time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003eProtected Extra-Low-Voltage as per IEC 60204-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, function\u003c\/th\u003e\n\u003ctd\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, connection type\u003c\/th\u003e\n\u003ctd\u003e4x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical input connection, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1 A-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection, input, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of inputs\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput characteristics\u003c\/th\u003e\n\u003ctd\u003eAs per IEC 61131-2, type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching level\u003c\/th\u003e\n\u003ctd\u003eSignal 0: \u0026lt;= 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput switching logic\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput debounce time\u003c\/th\u003e\n\u003ctd\u003e0.1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection inputs (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current of inputs per module\u003c\/th\u003e\n\u003ctd\u003e1.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation of inputs between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDigital inputs, electrical isolation of input - internal communication\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769643348123,"sku":"8129109","price":204.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129109-1.jpg?v=1781463918"},{"product_id":"8129110","title":"CPX-AP-A-8DO-M12-5P","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(incl. interlinking block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e91g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eAny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e30 m outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCover material\u003c\/th\u003e\n\u003ctd\u003ePBT-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-ring material\u003c\/th\u003e\n\u003ctd\u003eFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eDiagnostics per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnose per internal communication\u003c\/th\u003e\n\u003ctd\u003eLoad switch-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e1byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of outputs\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eConfiguration of voltage monitoring, load supply PL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003eProtected Extra-Low-Voltage as per IEC 60204-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations load\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage load\u003c\/th\u003e\n\u003ctd\u003eTypically 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, function\u003c\/th\u003e\n\u003ctd\u003eDigital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, connection type\u003c\/th\u003e\n\u003ctd\u003e4x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1 A-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical output connection, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for output, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristic curve outputs\u003c\/th\u003e\n\u003ctd\u003eAs per IEC 61131-2, type 0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching logic at outputs\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection outputs (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput delay with resistive load\u003c\/th\u003e\n\u003ctd\u003eSignal change 0-\u0026gt;1: \u0026lt; 200 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current of outputs per module\u003c\/th\u003e\n\u003ctd\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation of outputs between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation of outputs between channel - internal communication\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769643446427,"sku":"8129110","price":239.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129110-1.jpg?v=1781463920"},{"product_id":"8129111","title":"CPX-AP-A-12DI4DO-M12-5P","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(incl. interlinking block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e98g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eAny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e30 m outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCover material\u003c\/th\u003e\n\u003ctd\u003ePBT-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-ring material\u003c\/th\u003e\n\u003ctd\u003eFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003e(Outputs) Diagnostics per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnose per internal communication\u003c\/th\u003e\n\u003ctd\u003eLoad switch-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e2byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e1byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of outputs\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eConfiguration of voltage monitoring, load supply PL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel parameters\u003c\/th\u003e\n\u003ctd\u003eInput debounce time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003eProtected Extra-Low-Voltage as per IEC 60204-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations load\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage load\u003c\/th\u003e\n\u003ctd\u003eTypically 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, function\u003c\/th\u003e\n\u003ctd\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, connection type\u003c\/th\u003e\n\u003ctd\u003e6x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical input connection, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1 A-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection, input, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of inputs\u003c\/th\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput characteristics\u003c\/th\u003e\n\u003ctd\u003eAs per IEC 61131-2, type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching level\u003c\/th\u003e\n\u003ctd\u003eSignal 0: \u0026lt;= 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput switching logic\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput debounce time\u003c\/th\u003e\n\u003ctd\u003e0.1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection inputs (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current of inputs per module\u003c\/th\u003e\n\u003ctd\u003e1.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation of inputs between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDigital inputs, electrical isolation of input - internal communication\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, function\u003c\/th\u003e\n\u003ctd\u003eDigital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1 A-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical output connection, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for output, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristic curve outputs\u003c\/th\u003e\n\u003ctd\u003eAs per IEC 61131-2, type 0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching logic at outputs\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection outputs (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput delay with resistive load\u003c\/th\u003e\n\u003ctd\u003eSignal change 0-\u0026gt;1: \u0026lt; 200 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current of outputs per module\u003c\/th\u003e\n\u003ctd\u003e2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation of outputs between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation of outputs between channel - internal communication\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769643511963,"sku":"8129111","price":257.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129111-1.jpg?v=1781463922"},{"product_id":"8129112","title":"CPX-AP-A-16DI-D-M12-5P","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(incl. interlinking block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e96g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eAny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e30 m inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCover material\u003c\/th\u003e\n\u003ctd\u003ePBT-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-ring material\u003c\/th\u003e\n\u003ctd\u003eFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eDiagnostics per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnose per internal communication\u003c\/th\u003e\n\u003ctd\u003eCommunication error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e2byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel parameters\u003c\/th\u003e\n\u003ctd\u003eInput debounce time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003eProtected Extra-Low-Voltage as per IEC 60204-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 40 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, function\u003c\/th\u003e\n\u003ctd\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, connection type\u003c\/th\u003e\n\u003ctd\u003e8x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical input connection, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1 A-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection, input, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of inputs\u003c\/th\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput characteristics\u003c\/th\u003e\n\u003ctd\u003eAs per IEC 61131-2, type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching level\u003c\/th\u003e\n\u003ctd\u003eSignal 0: \u0026lt;= 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput switching logic\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput debounce time\u003c\/th\u003e\n\u003ctd\u003e0.1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection inputs (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current of inputs per module\u003c\/th\u003e\n\u003ctd\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation of inputs between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDigital inputs, electrical isolation of input - internal communication\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769643544731,"sku":"8129112","price":275.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129112-1.jpg?v=1781463924"},{"product_id":"8129241","title":"CPX-AP-A-PN-M12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(incl. interlinking block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e108g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eAny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e100 m PROFINET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCover material\u003c\/th\u003e\n\u003ctd\u003ePBT-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThreaded sleeve material\u003c\/th\u003e\n\u003ctd\u003eHigh-alloy stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-ring material\u003c\/th\u003e\n\u003ctd\u003eFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eDiagnostics per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eAPDD invalid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eLLDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, D-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, note on transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit, switched fast Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e1024byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e1024byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eConfiguration of voltage monitoring, load supply PL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal cycle time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eGSDML file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, function\u003c\/th\u003e\n\u003ctd\u003eSystem communication XF20 OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, D-coded as per EN 61076-2-114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, shielding\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003eProtected Extra-Low-Voltage as per IEC 60204-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations load\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage load\u003c\/th\u003e\n\u003ctd\u003eTypically 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769643577499,"sku":"8129241","price":565.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129241-1.jpg?v=1781463926"},{"product_id":"8129243","title":"CPX-AP-A-EC-M12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(incl. interlinking block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e113g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eAny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e100 m EtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCover material\u003c\/th\u003e\n\u003ctd\u003ePBT-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInspection window material\u003c\/th\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThreaded sleeve material\u003c\/th\u003e\n\u003ctd\u003eHigh-alloy stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-ring material\u003c\/th\u003e\n\u003ctd\u003eFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eDiagnostics per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eAPDD invalid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, D-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, note on transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit, switched fast Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e1024byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e1024byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eConfiguration of voltage monitoring, load supply PL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal cycle time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eESI file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, function\u003c\/th\u003e\n\u003ctd\u003eSystem communication XF20 OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, D-coded as per EN 61076-2-114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, shielding\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003eProtected Extra-Low-Voltage as per IEC 60204-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations load\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 95 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage load\u003c\/th\u003e\n\u003ctd\u003eTypically 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769643610267,"sku":"8129243","price":565.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129243-1.jpg?v=1781463928"},{"product_id":"8129244","title":"CPX-AP-A-EP-M12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(incl. interlinking block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e113g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eAny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e100 m Ethernet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCover material\u003c\/th\u003e\n\u003ctd\u003ePBT-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInspection window material\u003c\/th\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThreaded sleeve material\u003c\/th\u003e\n\u003ctd\u003eHigh-alloy stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-ring material\u003c\/th\u003e\n\u003ctd\u003eFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eDiagnostics per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eAPDD invalid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eACD (Address Conflict Detection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, D-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, note on transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit, switched fast Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e4096byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on inputs\u003c\/th\u003e\n\u003ctd\u003eEP: 488 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e4096byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on outputs\u003c\/th\u003e\n\u003ctd\u003eEP: 496 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eConfiguration of voltage monitoring, load supply PL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal cycle time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eEDS file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, function\u003c\/th\u003e\n\u003ctd\u003eSystem communication XF20 OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, D-coded as per EN 61076-2-114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, shielding\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003eProtected Extra-Low-Voltage as per IEC 60204-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations load\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 95 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage load\u003c\/th\u003e\n\u003ctd\u003eTypically 3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769643774107,"sku":"8129244","price":565.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129244-1.jpg?v=1781463929"},{"product_id":"8129245","title":"CPX-AP-A-PN-CU","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(incl. interlinking block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e167g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eAny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e100 m PROFINET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCover material\u003c\/th\u003e\n\u003ctd\u003ePBT-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of flange\u003c\/th\u003e\n\u003ctd\u003eDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eThreaded sleeve material\u003c\/th\u003e\n\u003ctd\u003eHigh-alloy stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-ring material\u003c\/th\u003e\n\u003ctd\u003eFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eDiagnostics per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eAPDD invalid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eLLDP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45 as per IEC 61076-3-117 (V14)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, note on transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit, switched fast Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e1024byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e1024byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eConfiguration of voltage monitoring, load supply PL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal cycle time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eGSDML file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, function\u003c\/th\u003e\n\u003ctd\u003eSystem communication XF20 OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, D-coded as per EN 61076-2-114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, shielding\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003eProtected Extra-Low-Voltage as per IEC 60204-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations load\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage load\u003c\/th\u003e\n\u003ctd\u003eTypically 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769643806875,"sku":"8129245","price":818.47,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129245-1.jpg?v=1781463931"},{"product_id":"8129251","title":"CPX-AP-A-SB","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(installation dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn H-rail with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e97g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eArbitrary, on H-rail: horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003ePU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003eProtected Extra-Low-Voltage as per IEC 60204-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769643839643,"sku":"8129251","price":62.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129251-1.jpg?v=1781463934"},{"product_id":"8129253","title":"CPX-AP-A-S-1-PP-5P","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(installation dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn H-rail with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e182g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eArbitrary, on H-rail: horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of flange\u003c\/th\u003e\n\u003ctd\u003eDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003ePU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load and functional earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003ePush-pull as per IEC 61076-3-126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00997378\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e2x24 V [XD1,PS,PL]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e2 x 10 A (external fuse required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769643872411,"sku":"8129253","price":194.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129253-1.jpg?v=1781463935"},{"product_id":"8129256","title":"CPX-AP-A-S-1-M12-5P","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(installation dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn H-rail with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e178g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eArbitrary, on H-rail: horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of flange\u003c\/th\u003e\n\u003ctd\u003eDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003ePU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load and functional earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, L-coded as per EN 61076-2-111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e2x24 V [XD1,PS,PL]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e2 x 10 A (external fuse required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769643937947,"sku":"8129256","price":194.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129256-1.jpg?v=1781463937"},{"product_id":"8129257","title":"CPX-AP-A-AR-1-PP-5P","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(installation dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn H-rail with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e177g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eArbitrary, on H-rail: horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of flange\u003c\/th\u003e\n\u003ctd\u003eDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003ePU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load and functional earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003ePush-pull as per IEC 61076-3-126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00997378\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V [XD-AR,PL]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e2 x 10 A (external fuse required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769643970715,"sku":"8129257","price":214.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129257-1.jpg?v=1781463939"},{"product_id":"8129260","title":"CPX-AP-A-AR-1-M12-5P","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(installation dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn H-rail with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e174g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eArbitrary, on H-rail: horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of flange\u003c\/th\u003e\n\u003ctd\u003eDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003ePU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load and functional earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, L-coded as per EN 61076-2-111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V [XD-AR,PL]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e2 x 10 A (external fuse required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769644003483,"sku":"8129260","price":214.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129260-1.jpg?v=1781463941"},{"product_id":"8129261","title":"CPX-AP-A-S-2-M12-5P","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(installation dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn H-rail with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e183g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eArbitrary, on H-rail: horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of flange\u003c\/th\u003e\n\u003ctd\u003eDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003ePU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eO-ring material\u003c\/th\u003e\n\u003ctd\u003eFPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load and functional earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, L-coded as per EN 61076-2-111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load and functional earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e2x24 V [XD1,PS,PL]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e2 x 16 A (external fuse required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769644036251,"sku":"8129261","price":311.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129261-1.jpg?v=1781463943"},{"product_id":"8129262","title":"CPX-AP-A-AL-1-PP-5P","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(installation dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn H-rail with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e177g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eArbitrary, on H-rail: horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of flange\u003c\/th\u003e\n\u003ctd\u003eDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003ePU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load and functional earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003ePush-pull as per IEC 61076-3-126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00997378\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V [XD-AL,PL]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e2 x 10 A (external fuse required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769644101787,"sku":"8129262","price":214.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129262-1.jpg?v=1781463946"},{"product_id":"8129263","title":"CPX-AP-A-AL-1-M12-5P","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e(installation dimensions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e50.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn H-rail with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e174g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eArbitrary, on H-rail: horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eObserve ambient temperature derating according to IEC 61131-2:2017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal altitude of use above sea level\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 2000 m ASL (\u0026gt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e3500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e\u0026gt; 2000 m ASL (\u0026lt; 79.5 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on vibration resistance\u003c\/th\u003e\n\u003ctd\u003eSG1 on H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on shock resistance\u003c\/th\u003e\n\u003ctd\u003e30 g\/11 ms as per EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial fire test\u003c\/th\u003e\n\u003ctd\u003eUL94 V-0 (housing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA-reinforced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of flange\u003c\/th\u003e\n\u003ctd\u003eDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003ePU foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load and functional earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, L-coded as per EN 61076-2-111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V [XD-AL,PL]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e2.5mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e2 x 10 A (external fuse required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePotential separation between the supply voltages electronics\/sensor technology and load\/valves\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769644167323,"sku":"8129263","price":214.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8129263-1.jpg?v=1781463947"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/collections\/8129263-1.jpg?v=1781720901","url":"https:\/\/festopneumatics.com\/collections\/remote-i-o-and-network-interface-components.oembed","provider":"Festo Pneumatics","version":"1.0","type":"link"}