{"title":"Mechanical hand operated valves","description":"\u003cp\u003eOperate pneumatic functions manually with Festo mechanical and hand-operated valves. Robust push-button, lever, and foot-operated designs support maintenance, setup, and safety-related control tasks.\u003c\/p\u003e","products":[{"product_id":"3192065","title":"VHER-H-B43C-G12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3200 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e1010 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingOptionally:With through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751808381083,"sku":"3192065","price":340.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192065-1.jpg?v=1781283736"},{"product_id":"3192066","title":"VHER-H-B43C-B-G12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e860 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingWith through-holeOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751808675995,"sku":"3192066","price":340.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192066-1.jpg?v=1781283737"},{"product_id":"3192067","title":"VHER-H-B43E-G12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3200 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995941\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e1010 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeFront panel mountingOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751808872603,"sku":"3192067","price":375.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192067-1.jpg?v=1781283740"},{"product_id":"3192068","title":"VHER-H-B43E-B-G12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995941\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e860 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:With through-holeFront panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751809134747,"sku":"3192068","price":375.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192068-1.jpg?v=1781283742"},{"product_id":"3192071","title":"VHER-H-B43U-G12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3200 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995943\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e1010 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:With through-holeFront panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751809724571,"sku":"3192071","price":375.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192071-1.jpg?v=1781283744"},{"product_id":"3192072","title":"VHER-H-B43U-B-G12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995943\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e860 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:Front panel mountingWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751810314395,"sku":"3192072","price":375.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192072-1.jpg?v=1781283746"},{"product_id":"3192074","title":"VHER-P-H-B43C-G12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3200 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e900 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeFront panel mountingOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751811526811,"sku":"3192074","price":298.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192074-1.jpg?v=1781283748"},{"product_id":"3192075","title":"VHER-P-H-B43C-B-G12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e740 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:With through-holeFront panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751812116635,"sku":"3192075","price":298.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192075-1.jpg?v=1781283749"},{"product_id":"3192076","title":"VHER-P-H-B43E-G12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3200 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995945\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e900 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:With through-holeFront panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751812247707,"sku":"3192076","price":329.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192076-1.jpg?v=1781283752"},{"product_id":"3192077","title":"VHER-P-H-B43E-B-G12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995945\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e740 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:With through-holeFront panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751812346011,"sku":"3192077","price":329.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192077-1.jpg?v=1781283753"},{"product_id":"3192082","title":"VHER-P-H-B43U-G12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3200 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995946\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e900 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingOptionally:With through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751812706459,"sku":"3192082","price":329.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192082-1.jpg?v=1781283755"},{"product_id":"3192084","title":"VHER-P-H-B43U-B-G12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995946\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e740 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeFront panel mountingOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751813034139,"sku":"3192084","price":329.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192084-1.jpg?v=1781283758"},{"product_id":"3192085","title":"VHER-H-B43C-N12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3200 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e1010 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeOptionally:Front panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751813230747,"sku":"3192085","price":340.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192085-1.jpg?v=1781283759"},{"product_id":"3192086","title":"VHER-H-B43C-B-N12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e860 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingOptionally:With through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751813656731,"sku":"3192086","price":340.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192086-1.jpg?v=1781283761"},{"product_id":"3192087","title":"VHER-H-B43E-N12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3200 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995941\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e1010 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeFront panel mountingOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751814115483,"sku":"3192087","price":375.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192087-1.jpg?v=1781283763"},{"product_id":"3192088","title":"VHER-H-B43E-B-N12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e3800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995941\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e860 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeOptionally:Front panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eNPT1\/2-14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751814639771,"sku":"3192088","price":375.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3192088-1.jpg?v=1781283765"},{"product_id":"3410679","title":"VHER-P-H-B43C-M5","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e37 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e170 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 2 (ATEX)Zone 22 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e95 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeOptionally:Front panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751840624795,"sku":"3410679","price":120.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3410679-1.jpg?v=1781283869"},{"product_id":"3410680","title":"VHER-P-H-B43C-B-M5","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e260 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 22 (ATEX)Zone 2 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e80 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingWith through-holeOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751841018011,"sku":"3410680","price":120.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3410680-1.jpg?v=1781283871"},{"product_id":"3410681","title":"VHER-P-H-B43E-M5","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e37 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e170 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995945\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 2 (ATEX)Zone 22 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e95 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:Front panel mountingWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751842099355,"sku":"3410681","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3410681-1.jpg?v=1781283873"},{"product_id":"3410682","title":"VHER-P-H-B43E-B-M5","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e260 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995945\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 22 (ATEX)Zone 2 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e80 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:Front panel mountingWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751842394267,"sku":"3410682","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3410682-1.jpg?v=1781283878"},{"product_id":"3410683","title":"VHER-P-H-B43U-M5","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e37 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e170 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995946\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 2 (ATEX)Zone 22 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e95 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeFront panel mountingOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751842558107,"sku":"3410683","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3410683-1.jpg?v=1781283877"},{"product_id":"3410684","title":"VHER-P-H-B43U-B-M5","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e260 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995946\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 22 (ATEX)Zone 2 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e80 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:Front panel mountingWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eM5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751842754715,"sku":"3410684","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3410684-1.jpg?v=1781283880"},{"product_id":"3488204","title":"VHER-H-B43C-G18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e600 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e260 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:Front panel mountingWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751864643739,"sku":"3488204","price":184.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488204-1.jpg?v=1781283967"},{"product_id":"3488205","title":"VHER-H-B43C-B-G18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingWith through-holeOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751864840347,"sku":"3488205","price":184.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488205-1.jpg?v=1781283970"},{"product_id":"3488206","title":"VHER-H-B43E-G18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e600 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995941\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e260 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeOptionally:Front panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751865135259,"sku":"3488206","price":192.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488206-1.jpg?v=1781283973"},{"product_id":"3488207","title":"VHER-H-B43E-B-G18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995941\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeOptionally:Front panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751865462939,"sku":"3488207","price":192.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488207-1.jpg?v=1781283975"},{"product_id":"3488208","title":"VHER-P-H-B43C-G18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e600 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 22 (ATEX)Zone 2 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e165 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:With through-holeFront panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751865594011,"sku":"3488208","price":131.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488208-1.jpg?v=1781283978"},{"product_id":"3488209","title":"VHER-P-H-B43C-B-G18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 2 (ATEX)Zone 22 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e125 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingOptionally:With through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751865987227,"sku":"3488209","price":131.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488209-1.jpg?v=1781283980"},{"product_id":"3488210","title":"VHER-P-H-B43E-G18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e600 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995945\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 22 (ATEX)Zone 2 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e165 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:Front panel mountingWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751866642587,"sku":"3488210","price":136.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488210-1.jpg?v=1781283983"},{"product_id":"3488211","title":"VHER-P-H-B43E-B-G18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995945\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 22 (ATEX)Zone 2 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e125 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:With through-holeFront panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751867461787,"sku":"3488211","price":136.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488211-1.jpg?v=1781283987"},{"product_id":"3488212","title":"VHER-H-B43C-N18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e600 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eNPT1\/8-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e260 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:Front panel mountingWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eNPT1\/8-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eNPT1\/8-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eNPT1\/8-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eNPT1\/8-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751867986075,"sku":"3488212","price":184.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488212-1.jpg?v=1781283989"},{"product_id":"3488213","title":"VHER-H-B43C-B-N18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eNPT1\/8-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:With through-holeFront panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eNPT1\/8-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eNPT1\/8-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eNPT1\/8-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eNPT1\/8-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751868379291,"sku":"3488213","price":184.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488213-1.jpg?v=1781283992"},{"product_id":"3488214","title":"VHER-H-B43U-G18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e600 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995943\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e260 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingWith through-holeOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751869001883,"sku":"3488214","price":192.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488214-1.jpg?v=1781283994"},{"product_id":"3488215","title":"VHER-H-B43U-B-G18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995943\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeOptionally:Front panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751869100187,"sku":"3488215","price":192.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488215-1.jpg?v=1781283996"},{"product_id":"3488216","title":"VHER-P-H-B43U-G18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e600 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995946\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 2 (ATEX)Zone 22 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e165 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingOptionally:With through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751869231259,"sku":"3488216","price":136.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488216-1.jpg?v=1781283998"},{"product_id":"3488217","title":"VHER-P-H-B43U-B-G18","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e800 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995946\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 22 (ATEX)Zone 2 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e0.9 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e125 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:With through-holeFront panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751869329563,"sku":"3488217","price":136.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3488217-1.jpg?v=1781284000"},{"product_id":"3514710","title":"VHER-H-B43C-G14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1150 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e560 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingWith through-holeOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eGÂ¼\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751870410907,"sku":"3514710","price":217.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3514710-1.jpg?v=1781284019"},{"product_id":"3515082","title":"VHER-H-B43E-G14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1150 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eIn dual pressure mode, the pressure at connection 1 must be higher than at connection 3.Vacuum operation between -0.95 and 0 bar may only be connected to connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995941\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e560 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:Front panel mountingWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eGÂ¼\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751870640283,"sku":"3515082","price":225.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3515082-1.jpg?v=1781284021"},{"product_id":"3515108","title":"VHER-H-B43U-G14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1150 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995943\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e560 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingWith through-holeOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eGÂ¼\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751870836891,"sku":"3515108","price":225.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3515108-1.jpg?v=1781284023"},{"product_id":"3515202","title":"VHER-H-B43C-B-G14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1500 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e510 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeFront panel mountingOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eGÂ¼\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751871099035,"sku":"3515202","price":217.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3515202-1.jpg?v=1781284025"},{"product_id":"3515258","title":"VHER-H-B43E-B-G14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1500 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995941\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e510 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingOptionally:With through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eGÂ¼\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751872606363,"sku":"3515258","price":225.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3515258-1.jpg?v=1781284027"},{"product_id":"3515286","title":"VHER-H-B43U-B-G14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1500 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995943\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e510 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeOptionally:Front panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eGÂ¼\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751873228955,"sku":"3515286","price":225.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3515286-1.jpg?v=1781284030"},{"product_id":"3515361","title":"VHER-P-H-B43C-G14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1150 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 2 (ATEX)Zone 22 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e435 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeFront panel mountingOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eGÂ¼\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751873949851,"sku":"3515361","price":190.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3515361-1.jpg?v=1781284032"},{"product_id":"3515542","title":"VHER-P-H-B43E-G14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1150 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995945\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 2 (ATEX)Zone 22 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e435 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeFront panel mountingOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eGÂ¼\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751875522715,"sku":"3515542","price":197.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3515542-1.jpg?v=1781284033"},{"product_id":"3515573","title":"VHER-P-H-B43U-G14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1150 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995946\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 2 (ATEX)Zone 22 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e435 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingWith through-holeOptionally:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eGÂ¼\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751876505755,"sku":"3515573","price":197.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3515573-1.jpg?v=1781284036"},{"product_id":"3515601","title":"VHER-P-H-B43C-B-G14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1500 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 2 (ATEX)Zone 22 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e375 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:Front panel mountingWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eGÂ¼\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751877750939,"sku":"3515601","price":190.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3515601-1.jpg?v=1781284038"},{"product_id":"3515640","title":"VHER-P-H-B43E-B-G14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, exhausted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1500 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995945\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 2 (ATEX)Zone 22 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e375 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingOptionally:With through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eGÂ¼\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751879323803,"sku":"3515640","price":197.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3515640-1.jpg?v=1781284040"},{"product_id":"3515683","title":"VHER-P-H-B43U-B-G14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, pressurized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1500 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuator lock\u003c\/th\u003e\n\u003ctd\u003ecan be closed with accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995946\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 22 (ATEX)Zone 2 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e375 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-holeOptionally:Front panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eGÂ¼\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eG1\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751880634523,"sku":"3515683","price":197.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3515683-1.jpg?v=1781284043"},{"product_id":"3520365","title":"VHER-H-B43C-N14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e66 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1150 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eNPT1\/4-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e560 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOptionally:With through-holeFront panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eNPT1\/4-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eNPT1\/4-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eNPT1\/4-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eNPT1\/4-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eFree of copper and PTFERoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751883813019,"sku":"3520365","price":217.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3520365-1.jpg?v=1781284046"},{"product_id":"3520389","title":"VHER-H-B43C-B-N14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve function\u003c\/th\u003e\n\u003ctd\u003e4\/3, closed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuation type\u003c\/th\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e56 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e1500 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic working port\u003c\/th\u003e\n\u003ctd\u003eNPT1\/4-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e0 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating pressure\u003c\/th\u003e\n\u003ctd\u003eVacuum operation between -0.95 and 0 bar may only be connected to connection 3.In dual pressure mode, the pressure at connection 1 must be higher than at connection 3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eRotary gate valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal width\u003c\/th\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVHER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExhaust air function\u003c\/th\u003e\n\u003ctd\u003eWith flow control option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication note\u003c\/th\u003e\n\u003ctd\u003eOperate by hand only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSealing principle\u003c\/th\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of control\u003c\/th\u003e\n\u003ctd\u003eDirect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow direction\u003c\/th\u003e\n\u003ctd\u003eNon-reversible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSymbol\u003c\/th\u003e\n\u003ctd\u003e00995942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUnderlap\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching position indication\u003c\/th\u003e\n\u003ctd\u003ewith accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication possible (required for further use)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 80 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActuating torque\u003c\/th\u003e\n\u003ctd\u003e2 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e510 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mountingOptionally:With through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 1\u003c\/th\u003e\n\u003ctd\u003eNPT1\/4-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eNPT1\/4-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 3\u003c\/th\u003e\n\u003ctd\u003eNPT1\/4-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eNPT1\/4-18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantFree of copper and PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751885680795,"sku":"3520389","price":217.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3520389-1.jpg?v=1781284052"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/collections\/5300047-1.jpg?v=1781720828","url":"https:\/\/festopneumatics.com\/collections\/pneumatic-valves-and-valve-manifolds-mechanical-hand-operated-valves.oembed","provider":"Festo Pneumatics","version":"1.0","type":"link"}