{"title":"Pzvt","description":null,"products":[{"product_id":"177616","title":"PZVT-120-SEC","description":"timer PZVT-120-SEC Design structure=mechanical sequence counter with pneumatic drive, Switch-off pressure=\u0026lt;= 0,1 bar, Operating pressure=2 - 6 bar, Switch-on pressure=\u0026gt;= 1,6 bar, Standard nominal flow rate=50 l\/min\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign structure\u003c\/th\u003e\n\u003ctd\u003emechanical sequence counter with pneumatic drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch-off pressure\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e2 ... 6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch-on pressure\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;= 1.6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdjustable delay times\u003c\/th\u003e\n\u003ctd\u003e8 ... 120 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting accuracy\u003c\/th\u003e\n\u003ctd\u003e± 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePause period for reset\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;= 200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepetition accuracy, time setting\u003c\/th\u003e\n\u003ctd\u003e± 1,2 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air in accordance with ISO8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on operating and pilot medium\u003c\/th\u003e\n\u003ctd\u003eLubricated operation not possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIP54to IEC 60529With protective cover and panel frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e'-10 ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48765869457563,"sku":"177616","price":579.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/177616-1.jpg?v=1781371807"},{"product_id":"158495","title":"PZVT-3-SEC","description":"timer PZVT-3-SEC Design structure=mechanical sequence counter with pneumatic drive, Switch-off pressure=\u0026lt;= 0,1 bar, Operating pressure=2 - 6 bar, Switch-on pressure=\u0026gt;= 1,6 bar, Standard nominal flow rate=50 l\/min\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign structure\u003c\/th\u003e\n\u003ctd\u003emechanical sequence counter with pneumatic drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch-off pressure\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e2 ... 6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch-on pressure\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;= 1.6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdjustable delay times\u003c\/th\u003e\n\u003ctd\u003e0.2 ... 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting accuracy\u003c\/th\u003e\n\u003ctd\u003e± 0,3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePause period for reset\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;= 200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepetition accuracy, time setting\u003c\/th\u003e\n\u003ctd\u003e± 0,1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air in accordance with ISO8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on operating and pilot medium\u003c\/th\u003e\n\u003ctd\u003eLubricated operation not possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIP54to IEC 60529With protective cover and panel frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e'-10 ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48765975429275,"sku":"158495","price":554.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/158495-1.jpg?v=1781374086"},{"product_id":"158496","title":"PZVT-AUT","description":"reset module PZVT-AUT Design structure=mechanical sequence counter with pneumatic drive, Switch-off pressure=\u0026lt;= 0,1 bar, Operating pressure=2 - 6 bar, Switch-on pressure=\u0026gt;= 1,6 bar, Standard nominal flow rate=50 l\/min\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign structure\u003c\/th\u003e\n\u003ctd\u003emechanical sequence counter with pneumatic drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch-off pressure\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;= 0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e2 ... 6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch-on pressure\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;= 1.6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdjustable delay times\u003c\/th\u003e\n\u003ctd\u003e0.2 ... 2 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePause period for reset\u003c\/th\u003e\n\u003ctd\u003e\u0026gt;= 200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepetition accuracy, time setting\u003c\/th\u003e\n\u003ctd\u003e± 0,3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air in accordance with ISO8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on operating and pilot medium\u003c\/th\u003e\n\u003ctd\u003eLubricated operation not possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eIP54to IEC 60529With protective cover and panel frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e'-15 ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48765975462043,"sku":"158496","price":423.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/158496-1.jpg?v=1781374089"},{"product_id":"13988","title":"PZVT-999-SEC-B","description":"timer PZVT-999-SEC-B With digital mode of operation Operating medium=Compressed air in accordance with ISO8573-1:2010 [7:4:4], Note on operating and pilot medium=Lubricated operation not possible\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air in accordance with ISO8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on operating and pilot medium\u003c\/th\u003e\n\u003ctd\u003eLubricated operation not possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766194090139,"sku":"13988","price":984.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/13988-1.jpg?v=1781380099"},{"product_id":"13989","title":"PZVT-99999-MIN-B","description":"timer PZVT-99999-MIN-B With digital mode of operation Operating medium=Compressed air in accordance with ISO8573-1:2010 [7:4:4], Note on operating and pilot medium=Lubricated operation not possible\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air in accordance with ISO8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on operating and pilot medium\u003c\/th\u003e\n\u003ctd\u003eLubricated operation not possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766194122907,"sku":"13989","price":1282.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/13989-1.jpg?v=1781380101"},{"product_id":"150238","title":"PZVT-30-SEC","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003ePZVT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eMechanical sequence counter with pneumatic actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch-off pressure\u003c\/th\u003e\n\u003ctd\u003eâ‰¤ 0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e2 bar ... 6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch-on pressure\u003c\/th\u003e\n\u003ctd\u003eâ‰¥ 1.6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdjustable delay time\u003c\/th\u003e\n\u003ctd\u003e2 s ... 30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting accuracy\u003c\/th\u003e\n\u003ctd\u003eÂ± 0.6 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePause period for reset\u003c\/th\u003e\n\u003ctd\u003eâ‰¥ 200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepetition accuracy of time setting\u003c\/th\u003e\n\u003ctd\u003eÂ± 0.3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 22 (ATEX)Zone 1 (ATEX)Zone 2 (ATEX)Zone 21 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication not possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP54With protective cap and panel frameas per IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 Â°C ... 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e45 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection\u003c\/th\u003e\n\u003ctd\u003eInternal thread M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766500503707,"sku":"150238","price":579.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/150238-1.jpg?v=1781388872"},{"product_id":"150239","title":"PZVT-300-SEC","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003ePZVT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDesign\u003c\/th\u003e\n\u003ctd\u003eMechanical sequence counter with pneumatic actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch-off pressure\u003c\/th\u003e\n\u003ctd\u003eâ‰¤ 0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e2 bar ... 6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitch-on pressure\u003c\/th\u003e\n\u003ctd\u003eâ‰¥ 1.6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandard nominal flow rate\u003c\/th\u003e\n\u003ctd\u003e50 l\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdjustable delay time\u003c\/th\u003e\n\u003ctd\u003e20 s ... 300 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSetting accuracy\u003c\/th\u003e\n\u003ctd\u003eÂ± 6 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePause period for reset\u003c\/th\u003e\n\u003ctd\u003eâ‰¥ 200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepetition accuracy of time setting\u003c\/th\u003e\n\u003ctd\u003eÂ± 3 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExplosion prevention and protection\u003c\/th\u003e\n\u003ctd\u003eZone 22 (ATEX)Zone 21 (ATEX)Zone 1 (ATEX)Zone 2 (ATEX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:4:4]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on operating and pilot media\u003c\/th\u003e\n\u003ctd\u003eOperation with oil lubrication not possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP54as per IEC 60529With protective cap and panel frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-10 Â°C ... 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e45 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eFront panel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection\u003c\/th\u003e\n\u003ctd\u003eInternal thread M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766500536475,"sku":"150239","price":579.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/150239-1.jpg?v=1781388874"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/collections\/150239-1.jpg?v=1781720849","url":"https:\/\/festopneumatics.com\/collections\/pneumatic-controls-pzvt.oembed","provider":"Festo Pneumatics","version":"1.0","type":"link"}