{"title":"Servo drive","description":"\u003cp\u003eFesto servo drives convert control commands into precise motor torque and speed. Compact drives support common fieldbuses and integrate with Festo engineering tools for fast startup and tuning.\u003c\/p\u003e","products":[{"product_id":"1501325","title":"CMMP-AS-C2-3A-M3","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCMMP-AS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eSeven-segment display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0 Hz ... 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x 0 - 270 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor\u003c\/th\u003e\n\u003ctd\u003e60 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eGalvanically isolatedFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e20 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e2.8 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e320 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal output current\u003c\/th\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e500 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e2 A ... 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz ... 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization interface\u003c\/th\u003e\n\u003ctd\u003eEthernetUSBParameterization and commissioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e1000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e0.208333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003eÂ± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directiveas per EU machinery directiveAs per EU low voltage directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e0 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20IP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0 Â°C ... 40 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003ec UL us - Listed (OL)RCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e2100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog monitor outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24Â VÂ DC\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eDS301\/DSP402FHPP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eFor 256 positioning blocksI\/O coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e8 V ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorking range of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution of monitor outputs\u003c\/th\u003e\n\u003ctd\u003e9 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003eResolution 16384 ppr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003eRS422HIPERFACEEnDatÂ®SINCOS3-phase encoder signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eShort circuit-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eConfigurable for currentConfigurable for rotational speedDifferential inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eFreely configurableGalvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eSetpoint specification for downstream slave actuator.Actual value feedback via encoder signals in speed control mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eEncoder signal speed setpoint value.As speed setting of the slave actuator in synchronous mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus connection\u003c\/th\u003e\n\u003ctd\u003ePlugSub-D9-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eProfibus DPCANopenEtherCATEtherNet\/IPDeviceNetPROFINETModbusÂ®\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. fieldbus transmission rate\u003c\/th\u003e\n\u003ctd\u003e1 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn sub-baseScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766860099739,"sku":"1501325","price":1890.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/1501325-1.jpg?v=1781398476"},{"product_id":"1501326","title":"CMMP-AS-C5-3A-M3","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCMMP-AS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eSeven-segment display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0 Hz ... 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x 0 - 270 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor\u003c\/th\u003e\n\u003ctd\u003e60 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some casesGalvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e20 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e2.8 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e320 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal output current\u003c\/th\u003e\n\u003ctd\u003e0.208333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e1000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e4 A ... 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e0.208333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz ... 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization interface\u003c\/th\u003e\n\u003ctd\u003eParameterization and commissioningEthernetUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e2000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e0.416666666666667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003eÂ± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eas per EU machinery directiveAs per EU EMC directiveAs per EU low voltage directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e0 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP10IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0 Â°C ... 40 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance markc UL us - Listed (OL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e2200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog monitor outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24Â VÂ DC\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eFHPPDS301\/DSP402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eI\/O couplingFor 256 positioning blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e8 V ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorking range of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution of monitor outputs\u003c\/th\u003e\n\u003ctd\u003e9 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003eResolution 16384 ppr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003eEnDatÂ®HIPERFACERS422SINCOS3-phase encoder signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eShort circuit-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eConfigurable for rotational speedConfigurable for currentDifferential inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eFreely configurableGalvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eActual value feedback via encoder signals in speed control mode.Setpoint specification for downstream slave actuator.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eAs speed setting of the slave actuator in synchronous mode.Encoder signal speed setpoint value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus connection\u003c\/th\u003e\n\u003ctd\u003e9-pinSub-DPlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eModbusÂ®\/TCPCANopenEtherNet\/IPProfibus DPDeviceNetPROFINETEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. fieldbus transmission rate\u003c\/th\u003e\n\u003ctd\u003e1 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eScrewed tightlyOn sub-base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766860132507,"sku":"1501326","price":2169.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/1501326-1.jpg?v=1781398477"},{"product_id":"1501327","title":"CMMP-AS-C5-11A-P3-M3","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCMMP-AS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eSeven-segment display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0 Hz ... 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x 0 - 360 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor\u003c\/th\u003e\n\u003ctd\u003e68 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some casesGalvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e20 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e8.5 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e560 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal output current\u003c\/th\u003e\n\u003ctd\u003e0.208333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e3000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e5.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e0.208333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz ... 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization interface\u003c\/th\u003e\n\u003ctd\u003eEthernetUSBParameterization and commissioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e6000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003eÂ± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eas per EU machinery directiveAs per EU EMC directiveAs per EU low voltage directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e0 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20IP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0 Â°C ... 40 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance markc UL us - Listed (OL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e3450 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog monitor outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24Â VÂ DC\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eFHPPDS301\/DSP402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eI\/O couplingFor 256 positioning blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e8 V ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorking range of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution of monitor outputs\u003c\/th\u003e\n\u003ctd\u003e9 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003eResolution 16384 ppr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003eEnDatÂ®HIPERFACE3-phase encoder signalsSINCOSRS422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eShort circuit-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eDifferential inputsConfigurable for currentConfigurable for rotational speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eFreely configurableGalvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eSetpoint specification for downstream slave actuator.Actual value feedback via encoder signals in speed control mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eAs speed setting of the slave actuator in synchronous mode.Encoder signal speed setpoint value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus connection\u003c\/th\u003e\n\u003ctd\u003e9-pinPlugSub-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eCANopenModbusÂ®\/TCPEtherCATDeviceNetEtherNet\/IPProfibus DPPROFINET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. fieldbus transmission rate\u003c\/th\u003e\n\u003ctd\u003e1 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn sub-baseScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766860198043,"sku":"1501327","price":2867.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/1501327-1.jpg?v=1781398480"},{"product_id":"1501328","title":"CMMP-AS-C10-11A-P3-M3","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCMMP-AS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eSeven-segment display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0 Hz ... 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x 0 - 360 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor\u003c\/th\u003e\n\u003ctd\u003e68 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eGalvanically isolatedFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e20 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e8.5 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e560 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal output current\u003c\/th\u003e\n\u003ctd\u003e0.416666666666667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e6000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e0.458333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e0.416666666666667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz ... 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization interface\u003c\/th\u003e\n\u003ctd\u003eParameterization and commissioningEthernetUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e12000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003eÂ± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directiveAs per EU low voltage directiveas per EU machinery directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e0 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP10IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0 Â°C ... 40 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance markc UL us - Listed (OL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e3450 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog monitor outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24Â VÂ DC\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eDS301\/DSP402FHPP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eFor 256 positioning blocksI\/O coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e8 V ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorking range of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution of monitor outputs\u003c\/th\u003e\n\u003ctd\u003e9 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003eResolution 16384 ppr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003eRS422HIPERFACE3-phase encoder signalsSINCOSEnDatÂ®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eShort circuit-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eConfigurable for rotational speedDifferential inputsConfigurable for current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eGalvanically isolatedFreely configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eActual value feedback via encoder signals in speed control mode.Setpoint specification for downstream slave actuator.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eEncoder signal speed setpoint value.As speed setting of the slave actuator in synchronous mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus connection\u003c\/th\u003e\n\u003ctd\u003ePlugSub-D9-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eCANopenProfibus DPPROFINETEtherCATModbusÂ®\/TCPEtherNet\/IPDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. fieldbus transmission rate\u003c\/th\u003e\n\u003ctd\u003e1 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn sub-baseScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766860918939,"sku":"1501328","price":3349.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/1501328-1.jpg?v=1781398482"},{"product_id":"1622901","title":"CMMP-AS-C2-3A-M0","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCMMP-AS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActive PFC\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety function\u003c\/th\u003e\n\u003ctd\u003eSafe stop 1 (SS1)Safe torque off (STO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety integrity level (SIL)\u003c\/th\u003e\n\u003ctd\u003eSafe torque off (STO)\/SIL 3\/SILCL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Level (PL)\u003c\/th\u003e\n\u003ctd\u003eSafe torque off (STO)\/category 4, performance level e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eSeven-segment display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0 Hz ... 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x 0 - 270 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor\u003c\/th\u003e\n\u003ctd\u003e60 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic coverage\u003c\/th\u003e\n\u003ctd\u003e0.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some casesGalvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware fault tolerance\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e20 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e2.8 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e320 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal output current\u003c\/th\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e500 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e2 A ... 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz ... 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization interface\u003c\/th\u003e\n\u003ctd\u003eUSBEthernetParameterization and commissioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSFF safe failure fraction\u003c\/th\u003e\n\u003ctd\u003e0.9917\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e1000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e0.208333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply without clamping brake\u003c\/th\u003e\n\u003ctd\u003e0.55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003eÂ± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertificate issuing authority\u003c\/th\u003e\n\u003ctd\u003eGerman Technical Control Board (TÃœV) Rheinland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU low voltage directiveas per EU machinery directiveAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e0 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20IP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0 Â°C ... 40 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance markc UL us - Listed (OL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof test interval\u003c\/th\u003e\n\u003ctd\u003e20 y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e2100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog monitor outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24Â VÂ DC\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eDS301\/DSP402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eFor 256 positioning blocksI\/O coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e8 V ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorking range of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution of monitor outputs\u003c\/th\u003e\n\u003ctd\u003e9 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003eResolution 16384 ppr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003eRS422EnDatÂ®SINCOSHIPERFACE3-phase encoder signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eShort circuit-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eConfigurable for currentConfigurable for rotational speedDifferential inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eFreely configurableGalvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eActual value feedback via encoder signals in speed control mode.Setpoint specification for downstream slave actuator.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eAs speed setting of the slave actuator in synchronous mode.Encoder signal speed setpoint value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus connection\u003c\/th\u003e\n\u003ctd\u003eSub-D9-pinSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eCANopenModbusÂ®\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. fieldbus transmission rate\u003c\/th\u003e\n\u003ctd\u003e1 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn sub-baseScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766862688411,"sku":"1622901","price":1715.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/1622901-1.jpg?v=1781398527"},{"product_id":"1622902","title":"CMMP-AS-C5-3A-M0","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCMMP-AS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActive PFC\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety function\u003c\/th\u003e\n\u003ctd\u003eSafe stop 1 (SS1)Safe torque off (STO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety integrity level (SIL)\u003c\/th\u003e\n\u003ctd\u003eSafe torque off (STO)\/SIL 3\/SILCL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Level (PL)\u003c\/th\u003e\n\u003ctd\u003eSafe torque off (STO)\/category 4, performance level e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eSeven-segment display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0 Hz ... 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x 0 - 270 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor\u003c\/th\u003e\n\u003ctd\u003e60 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic coverage\u003c\/th\u003e\n\u003ctd\u003e0.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some casesGalvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware fault tolerance\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e20 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e2.8 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e320 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal output current\u003c\/th\u003e\n\u003ctd\u003e0.208333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e1000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e4 A ... 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz ... 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization interface\u003c\/th\u003e\n\u003ctd\u003eEthernetUSBParameterization and commissioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSFF safe failure fraction\u003c\/th\u003e\n\u003ctd\u003e0.9917\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e2000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e0.416666666666667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply without clamping brake\u003c\/th\u003e\n\u003ctd\u003e0.65 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003eÂ± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertificate issuing authority\u003c\/th\u003e\n\u003ctd\u003eGerman Technical Control Board (TÃœV) Rheinland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eas per EU machinery directiveAs per EU low voltage directiveAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e0 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20IP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0 Â°C ... 40 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003ec UL us - Listed (OL)RCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof test interval\u003c\/th\u003e\n\u003ctd\u003e20 y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e2200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog monitor outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24Â VÂ DC\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eDS301\/DSP402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eFor 256 positioning blocksI\/O coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e8 V ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorking range of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution of monitor outputs\u003c\/th\u003e\n\u003ctd\u003e9 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003eResolution 16384 ppr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003eSINCOS3-phase encoder signalsEnDatÂ®HIPERFACERS422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eShort circuit-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eConfigurable for currentDifferential inputsConfigurable for rotational speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eGalvanically isolatedFreely configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eSetpoint specification for downstream slave actuator.Actual value feedback via encoder signals in speed control mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eAs speed setting of the slave actuator in synchronous mode.Encoder signal speed setpoint value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus connection\u003c\/th\u003e\n\u003ctd\u003e9-pinPlugSub-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eModbusÂ®\/TCPCANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. fieldbus transmission rate\u003c\/th\u003e\n\u003ctd\u003e1 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eScrewed tightlyOn sub-base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766862721179,"sku":"1622902","price":1997.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/1622902-1.jpg?v=1781398528"},{"product_id":"1622903","title":"CMMP-AS-C5-11A-P3-M0","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCMMP-AS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety function\u003c\/th\u003e\n\u003ctd\u003eSafe torque off (STO)Safe stop 1 (SS1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety integrity level (SIL)\u003c\/th\u003e\n\u003ctd\u003eSafe torque off (STO)\/SIL 3\/SILCL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Level (PL)\u003c\/th\u003e\n\u003ctd\u003eSafe torque off (STO)\/category 4, performance level e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eSeven-segment display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0 Hz ... 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x 0 - 360 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor\u003c\/th\u003e\n\u003ctd\u003e68 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic coverage\u003c\/th\u003e\n\u003ctd\u003e0.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eGalvanically isolatedFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware fault tolerance\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e20 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e8.5 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e560 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal output current\u003c\/th\u003e\n\u003ctd\u003e0.208333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e3000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e5.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e0.208333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization interface\u003c\/th\u003e\n\u003ctd\u003eParameterization and commissioningEthernetUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSFF safe failure fraction\u003c\/th\u003e\n\u003ctd\u003e0.9917\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e6000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply without clamping brake\u003c\/th\u003e\n\u003ctd\u003e0.0416666666666667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003eÂ± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertificate issuing authority\u003c\/th\u003e\n\u003ctd\u003eGerman Technical Control Board (TÃœV) Rheinland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directiveas per EU machinery directiveAs per EU low voltage directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e0 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP10IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0 Â°C ... 40 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance markc UL us - Listed (OL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof test interval\u003c\/th\u003e\n\u003ctd\u003e20 y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e3800 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog monitor outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24Â VÂ DC\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eDS301\/DSP402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eI\/O couplingFor 256 positioning blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e8 V ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorking range of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution of monitor outputs\u003c\/th\u003e\n\u003ctd\u003e9 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003eResolution 16384 ppr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003eRS422SINCOSEnDatÂ®HIPERFACE3-phase encoder signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eShort circuit-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eConfigurable for rotational speedDifferential inputsConfigurable for current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eFreely configurableGalvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eActual value feedback via encoder signals in speed control mode.Setpoint specification for downstream slave actuator.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eAs speed setting of the slave actuator in synchronous mode.Encoder signal speed setpoint value.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus connection\u003c\/th\u003e\n\u003ctd\u003ePlug9-pinSub-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eCANopenModbusÂ®\/TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. fieldbus transmission rate\u003c\/th\u003e\n\u003ctd\u003e1 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn sub-baseScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766862983323,"sku":"1622903","price":2696.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/1622903-1.jpg?v=1781398530"},{"product_id":"1622904","title":"CMMP-AS-C10-11A-P3-M0","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCMMP-AS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety function\u003c\/th\u003e\n\u003ctd\u003eSafe torque off (STO)Safe stop 1 (SS1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety integrity level (SIL)\u003c\/th\u003e\n\u003ctd\u003eSafe torque off (STO)\/SIL 3\/SILCL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Level (PL)\u003c\/th\u003e\n\u003ctd\u003eSafe torque off (STO)\/category 4, performance level e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eSeven-segment display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0 Hz ... 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x 0 - 360 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor\u003c\/th\u003e\n\u003ctd\u003e68 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic coverage\u003c\/th\u003e\n\u003ctd\u003e0.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eGalvanically isolatedFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware fault tolerance\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e20 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e8.5 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e560 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal output current\u003c\/th\u003e\n\u003ctd\u003e0.416666666666667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e6000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e0.458333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e0.416666666666667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization interface\u003c\/th\u003e\n\u003ctd\u003eUSBEthernetParameterization and commissioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSFF safe failure fraction\u003c\/th\u003e\n\u003ctd\u003e0.9917\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e12000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply without clamping brake\u003c\/th\u003e\n\u003ctd\u003e0.0416666666666667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003eÂ± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertificate issuing authority\u003c\/th\u003e\n\u003ctd\u003eGerman Technical Control Board (TÃœV) Rheinland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directiveAs per EU low voltage directiveas per EU machinery directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e0 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP10IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0 Â°C ... 40 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance markc UL us - Listed (OL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProof test interval\u003c\/th\u003e\n\u003ctd\u003e20 y\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e3800 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog monitor outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24Â VÂ DC\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eDS301\/DSP402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eFor 256 positioning blocksI\/O coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e8 V ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorking range of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution of monitor outputs\u003c\/th\u003e\n\u003ctd\u003e9 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003eResolution 16384 ppr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003eSINCOSRS4223-phase encoder signalsHIPERFACEEnDatÂ®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eShort circuit-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eConfigurable for currentDifferential inputsConfigurable for rotational speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eGalvanically isolatedFreely configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eActual value feedback via encoder signals in speed control mode.Setpoint specification for downstream slave actuator.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eEncoder signal speed setpoint value.As speed setting of the slave actuator in synchronous mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus connection\u003c\/th\u003e\n\u003ctd\u003ePlug9-pinSub-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eModbusÂ®\/TCPCANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. fieldbus transmission rate\u003c\/th\u003e\n\u003ctd\u003e1 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn sub-baseScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766863016091,"sku":"1622904","price":3183.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/1622904-1.jpg?v=1781398532"},{"product_id":"3215473","title":"CMMP-AS-C15-11A-P3-M3","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCMMP-AS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eSeven-segment display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0 Hz ... 1000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x 0 - 360 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor\u003c\/th\u003e\n\u003ctd\u003e68 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some casesGalvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e20 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e8.5 kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e560 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal output current\u003c\/th\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e9000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current\u003c\/th\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e50 Hz ... 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization interface\u003c\/th\u003e\n\u003ctd\u003eUSBParameterization and commissioningEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e18000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003eÂ± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directiveas per EU machinery directiveAs per EU low voltage directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e0 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20IP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0 Â°C ... 40 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003ec UL us - Listed (OL)RCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e3450 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog monitor outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24Â VÂ DC\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eDS301\/DSP402FHPP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eI\/O couplingFor 256 positioning blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e8 V ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorking range of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003eÂ± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eResolution of monitor outputs\u003c\/th\u003e\n\u003ctd\u003e9 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003eResolution 16384 ppr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003eSINCOSHIPERFACERS422EnDatÂ®3-phase encoder signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of monitor outputs\u003c\/th\u003e\n\u003ctd\u003eShort circuit-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eConfigurable for rotational speedDifferential inputsConfigurable for current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eFreely configurableGalvanically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eActual value feedback via encoder signals in speed control mode.Setpoint specification for downstream slave actuator.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput encoder interface, function\u003c\/th\u003e\n\u003ctd\u003eEncoder signal speed setpoint value.As speed setting of the slave actuator in synchronous mode.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBus connection\u003c\/th\u003e\n\u003ctd\u003eSub-D9-pinPlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eDeviceNetProfibus DPPROFINETEtherNet\/IPModbusÂ®\/TCPCANopenEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. fieldbus transmission rate\u003c\/th\u003e\n\u003ctd\u003e1 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eOn sub-baseScrewed tightly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantContains paint-wetting impairment substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766903091355,"sku":"3215473","price":4266.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/3215473-1.jpg?v=1781398887"},{"product_id":"8143164","title":"CMMT-AS-C4-3A-MP-S1","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eMounting plate, screwed on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eFree convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e1400g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eLED green\/yellow\/red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eOptional: CDSB operating unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConforms to standard\u003c\/th\u003e\n\u003ctd\u003eEN 61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBased on norm\u003c\/th\u003e\n\u003ctd\u003eEN 50581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKC characters\u003c\/th\u003e\n\u003ctd\u003eKC EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUKCA marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eTo UK instructions for EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertificate issuing authority\u003c\/th\u003e\n\u003ctd\u003eGerman Technical Control Board (TÜV) Rheinland 01\/205\/5640.00\/18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eAbove an ambient temperature of 40 °C, the power must be reduced by 3%\/°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUL-ambient temperature\u003c\/th\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e1% power reduction\/100 m above 1000 m.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurge resistance\u003c\/th\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364 zone III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e-20 % \/ +15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e48Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current load supply\u003c\/th\u003e\n\u003ctd\u003e5.6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current, load supply\u003c\/th\u003e\n\u003ctd\u003e16.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActive PFC\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem voltage to EN 61800-5-1\u003c\/th\u003e\n\u003ctd\u003e300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. short circuit protection of mains\u003c\/th\u003e\n\u003ctd\u003e100kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains types\u003c\/th\u003e\n\u003ctd\u003eTT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, load supply DC\u003c\/th\u003e\n\u003ctd\u003e320V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad supply permissible range\u003c\/th\u003e\n\u003ctd\u003e-20 %\/+15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e395V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor, integrated\u003c\/th\u003e\n\u003ctd\u003e100Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e1.6kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse energy for braking resistor\u003c\/th\u003e\n\u003ctd\u003e230Ws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor nominal power (IEC)\u003c\/th\u003e\n\u003ctd\u003e23W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor, external\u003c\/th\u003e\n\u003ctd\u003e67Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. continuous output of the external braking resistor (IEC)\u003c\/th\u003e\n\u003ctd\u003e350W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003e± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply without clamping brake\u003c\/th\u003e\n\u003ctd\u003e0.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply with parking brake\u003c\/th\u003e\n\u003ctd\u003e1.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply with clamping brake and I\/O\u003c\/th\u003e\n\u003ctd\u003e2.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x (0 – input) V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e2s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e700VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e2000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. length of motor cable without ext. mains filter\u003c\/th\u003e\n\u003ctd\u003e25m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. output current of holding brake\u003c\/th\u003e\n\u003ctd\u003e1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. voltage drop from logic supply to brake output\u003c\/th\u003e\n\u003ctd\u003e0.8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inputs for motor temperature sensor\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController operating mode\u003c\/th\u003e\n\u003ctd\u003eCascade control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMode of operation\u003c\/th\u003e\n\u003ctd\u003eField-oriented regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, function\u003c\/th\u003e\n\u003ctd\u003eParameterization and commissioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, protocol\u003c\/th\u003e\n\u003ctd\u003eTCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eCiA402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eAC1: Adjustable-Speed Drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface, function\u003c\/th\u003e\n\u003ctd\u003eBiSS-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface 2, function\u003c\/th\u003e\n\u003ctd\u003eIncremental encoder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronization interface, function\u003c\/th\u003e\n\u003ctd\u003eEncoder emulation A\/B\/Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003e1 MHz maximum output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003e1 MHz maximum output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput switching logic\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLogic input specification\u003c\/th\u003e\n\u003ctd\u003eBased on IEC 61131-2, type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e-3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of high-speed logic inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime resolution of high-speed logic inputs\u003c\/th\u003e\n\u003ctd\u003e1µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24 V DC\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching logic at outputs\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of high-speed switching outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime resolution of high-speed switching outputs\u003c\/th\u003e\n\u003ctd\u003e1µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of floating switching outputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of the floating switching outputs\u003c\/th\u003e\n\u003ctd\u003e50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eDifferential inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003e± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating range of analog inputs\u003c\/th\u003e\n\u003ctd\u003e± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e70kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety function\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety integrity level (SIL)\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\/SIL 3\/SILCL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Level (PL)\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\/category 3, performance level e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic coverage\u003c\/th\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSFF safe failure fraction\u003c\/th\u003e\n\u003ctd\u003e99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware fault tolerance\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of safe 2-pin inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of diagnostic outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769608679579,"sku":"8143164","price":1768.07,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8143164-1.jpg?v=1781462743"},{"product_id":"8143165","title":"CMMT-AS-C2-11A-P3-MP-S1","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eMounting plate, screwed on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eFree convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e2100g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eLED green\/yellow\/red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eOptional: CDSB operating unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConforms to standard\u003c\/th\u003e\n\u003ctd\u003eEN 61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBased on norm\u003c\/th\u003e\n\u003ctd\u003eEN 50581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKC characters\u003c\/th\u003e\n\u003ctd\u003eKC EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUKCA marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eTo UK instructions for EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertificate issuing authority\u003c\/th\u003e\n\u003ctd\u003eGerman Technical Control Board (TÜV) Rheinland 01\/205\/5640.00\/18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eAbove an ambient temperature of 40 °C, the power must be reduced by 3%\/°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUL-ambient temperature\u003c\/th\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e1% power reduction\/100 m above 1000 m.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurge resistance\u003c\/th\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364 zone III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e48Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current load supply\u003c\/th\u003e\n\u003ctd\u003e2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current, load supply\u003c\/th\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActive PFC\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem voltage to EN 61800-5-1\u003c\/th\u003e\n\u003ctd\u003e300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. short circuit protection of mains\u003c\/th\u003e\n\u003ctd\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains types\u003c\/th\u003e\n\u003ctd\u003eTN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, load supply DC\u003c\/th\u003e\n\u003ctd\u003e560V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad supply permissible range\u003c\/th\u003e\n\u003ctd\u003e± 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e800V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor, integrated\u003c\/th\u003e\n\u003ctd\u003e130Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e5kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse energy for braking resistor\u003c\/th\u003e\n\u003ctd\u003e850Ws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor nominal power (IEC)\u003c\/th\u003e\n\u003ctd\u003e48W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor, external\u003c\/th\u003e\n\u003ctd\u003e130Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. continuous output of the external braking resistor (IEC)\u003c\/th\u003e\n\u003ctd\u003e400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003e± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply without clamping brake\u003c\/th\u003e\n\u003ctd\u003e0.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply with parking brake\u003c\/th\u003e\n\u003ctd\u003e1.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply with clamping brake and I\/O\u003c\/th\u003e\n\u003ctd\u003e2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x (0 – input) V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e1.7A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e5.1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e2s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e800VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e2400VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. length of motor cable without ext. mains filter\u003c\/th\u003e\n\u003ctd\u003e50m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. output current of holding brake\u003c\/th\u003e\n\u003ctd\u003e1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. voltage drop from logic supply to brake output\u003c\/th\u003e\n\u003ctd\u003e0.8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inputs for motor temperature sensor\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController operating mode\u003c\/th\u003e\n\u003ctd\u003eCascade control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMode of operation\u003c\/th\u003e\n\u003ctd\u003eField-oriented regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, function\u003c\/th\u003e\n\u003ctd\u003eParameterization and commissioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, protocol\u003c\/th\u003e\n\u003ctd\u003eTCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eCiA402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eAC1: Adjustable-Speed Drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface, function\u003c\/th\u003e\n\u003ctd\u003eBiSS-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface 2, function\u003c\/th\u003e\n\u003ctd\u003eIncremental encoder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronization interface, function\u003c\/th\u003e\n\u003ctd\u003eEncoder emulation A\/B\/Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003e1 MHz maximum output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003e1 MHz maximum output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput switching logic\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLogic input specification\u003c\/th\u003e\n\u003ctd\u003eBased on IEC 61131-2, type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e-3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of high-speed logic inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime resolution of high-speed logic inputs\u003c\/th\u003e\n\u003ctd\u003e1µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24 V DC\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching logic at outputs\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of high-speed switching outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime resolution of high-speed switching outputs\u003c\/th\u003e\n\u003ctd\u003e1µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of floating switching outputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of the floating switching outputs\u003c\/th\u003e\n\u003ctd\u003e50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eDifferential inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003e± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating range of analog inputs\u003c\/th\u003e\n\u003ctd\u003e± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e70kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety function\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety integrity level (SIL)\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\/SIL 3\/SILCL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Level (PL)\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\/category 3, performance level e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic coverage\u003c\/th\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSFF safe failure fraction\u003c\/th\u003e\n\u003ctd\u003e99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware fault tolerance\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of safe 2-pin inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of diagnostic outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769608712347,"sku":"8143165","price":1897.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8143165-1.jpg?v=1781462744"},{"product_id":"8143166","title":"CMMT-AS-C3-11A-P3-MP-S1","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eMounting plate, screwed on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eFree convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e2100g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eLED green\/yellow\/red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eOptional: CDSB operating unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConforms to standard\u003c\/th\u003e\n\u003ctd\u003eEN 61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBased on norm\u003c\/th\u003e\n\u003ctd\u003eEN 50581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKC characters\u003c\/th\u003e\n\u003ctd\u003eKC EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUKCA marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eTo UK instructions for EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertificate issuing authority\u003c\/th\u003e\n\u003ctd\u003eGerman Technical Control Board (TÜV) Rheinland 01\/205\/5640.00\/18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eAbove an ambient temperature of 40 °C, the power must be reduced by 3%\/°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUL-ambient temperature\u003c\/th\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e1% power reduction\/100 m above 1000 m.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurge resistance\u003c\/th\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364 zone III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e48Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current load supply\u003c\/th\u003e\n\u003ctd\u003e3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current, load supply\u003c\/th\u003e\n\u003ctd\u003e9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActive PFC\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem voltage to EN 61800-5-1\u003c\/th\u003e\n\u003ctd\u003e300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. short circuit protection of mains\u003c\/th\u003e\n\u003ctd\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains types\u003c\/th\u003e\n\u003ctd\u003eTN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, load supply DC\u003c\/th\u003e\n\u003ctd\u003e560V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad supply permissible range\u003c\/th\u003e\n\u003ctd\u003e± 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e800V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor, integrated\u003c\/th\u003e\n\u003ctd\u003e130Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e5kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse energy for braking resistor\u003c\/th\u003e\n\u003ctd\u003e850Ws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor nominal power (IEC)\u003c\/th\u003e\n\u003ctd\u003e48W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor, external\u003c\/th\u003e\n\u003ctd\u003e130Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. continuous output of the external braking resistor (IEC)\u003c\/th\u003e\n\u003ctd\u003e600W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003e± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply without clamping brake\u003c\/th\u003e\n\u003ctd\u003e0.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply with parking brake\u003c\/th\u003e\n\u003ctd\u003e1.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply with clamping brake and I\/O\u003c\/th\u003e\n\u003ctd\u003e2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x (0 – input) V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e7.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e2s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e1200VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e3600VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. length of motor cable without ext. mains filter\u003c\/th\u003e\n\u003ctd\u003e50m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. output current of holding brake\u003c\/th\u003e\n\u003ctd\u003e1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. voltage drop from logic supply to brake output\u003c\/th\u003e\n\u003ctd\u003e0.8V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inputs for motor temperature sensor\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController operating mode\u003c\/th\u003e\n\u003ctd\u003eCascade control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMode of operation\u003c\/th\u003e\n\u003ctd\u003eField-oriented regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, function\u003c\/th\u003e\n\u003ctd\u003eParameterization and commissioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, protocol\u003c\/th\u003e\n\u003ctd\u003eTCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eCiA402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eAC1: Adjustable-Speed Drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface, function\u003c\/th\u003e\n\u003ctd\u003eBiSS-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface 2, function\u003c\/th\u003e\n\u003ctd\u003eIncremental encoder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronization interface, function\u003c\/th\u003e\n\u003ctd\u003eEncoder emulation A\/B\/Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003e1 MHz maximum output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003e1 MHz maximum output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput switching logic\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLogic input specification\u003c\/th\u003e\n\u003ctd\u003eBased on IEC 61131-2, type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e-3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of high-speed logic inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime resolution of high-speed logic inputs\u003c\/th\u003e\n\u003ctd\u003e1µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24 V DC\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching logic at outputs\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of high-speed switching outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime resolution of high-speed switching outputs\u003c\/th\u003e\n\u003ctd\u003e1µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of floating switching outputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of the floating switching outputs\u003c\/th\u003e\n\u003ctd\u003e50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eDifferential inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003e± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating range of analog inputs\u003c\/th\u003e\n\u003ctd\u003e± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e70kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety function\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety integrity level (SIL)\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\/SIL 3\/SILCL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Level (PL)\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\/category 3, performance level e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic coverage\u003c\/th\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSFF safe failure fraction\u003c\/th\u003e\n\u003ctd\u003e99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware fault tolerance\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of safe 2-pin inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of diagnostic outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769608745115,"sku":"8143166","price":2003.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8143166-1.jpg?v=1781462746"},{"product_id":"8143167","title":"CMMT-AS-C5-11A-P3-MP-S1","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eMounting plate, screwed on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eFree convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e2200g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eLED green\/yellow\/red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eOptional: CDSB operating unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConforms to standard\u003c\/th\u003e\n\u003ctd\u003eEN 61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBased on norm\u003c\/th\u003e\n\u003ctd\u003eEN 50581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKC characters\u003c\/th\u003e\n\u003ctd\u003eKC EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUKCA marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eTo UK instructions for EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertificate issuing authority\u003c\/th\u003e\n\u003ctd\u003eGerman Technical Control Board (TÜV) Rheinland 01\/205\/5640.00\/18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eAbove an ambient temperature of 40 °C, the power must be reduced by 3%\/°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUL-ambient temperature\u003c\/th\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e1% power reduction\/100 m above 1000 m.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurge resistance\u003c\/th\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364 zone III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e48Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current load supply\u003c\/th\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current, load supply\u003c\/th\u003e\n\u003ctd\u003e18A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActive PFC\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem voltage to EN 61800-5-1\u003c\/th\u003e\n\u003ctd\u003e300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. short circuit protection of mains\u003c\/th\u003e\n\u003ctd\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains types\u003c\/th\u003e\n\u003ctd\u003eTN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, load supply DC\u003c\/th\u003e\n\u003ctd\u003e560V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad supply permissible range\u003c\/th\u003e\n\u003ctd\u003e± 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e800V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor, integrated\u003c\/th\u003e\n\u003ctd\u003e130Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e5kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse energy for braking resistor\u003c\/th\u003e\n\u003ctd\u003e850Ws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor nominal power (IEC)\u003c\/th\u003e\n\u003ctd\u003e58W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor, external\u003c\/th\u003e\n\u003ctd\u003e80Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. continuous output of the external braking resistor (IEC)\u003c\/th\u003e\n\u003ctd\u003e1200W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003e± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply without clamping brake\u003c\/th\u003e\n\u003ctd\u003e0.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply with parking brake\u003c\/th\u003e\n\u003ctd\u003e1.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply with clamping brake and I\/O\u003c\/th\u003e\n\u003ctd\u003e2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x (0 – input) V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e2s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e2500VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e7500VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. length of motor cable without ext. mains filter\u003c\/th\u003e\n\u003ctd\u003e50m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. output current of holding brake\u003c\/th\u003e\n\u003ctd\u003e1.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. voltage drop from logic supply to brake output\u003c\/th\u003e\n\u003ctd\u003e1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inputs for motor temperature sensor\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController operating mode\u003c\/th\u003e\n\u003ctd\u003eCascade control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMode of operation\u003c\/th\u003e\n\u003ctd\u003eField-oriented regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, function\u003c\/th\u003e\n\u003ctd\u003eParameterization and commissioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, protocol\u003c\/th\u003e\n\u003ctd\u003eTCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eCiA402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eAC1: Adjustable-Speed Drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface, function\u003c\/th\u003e\n\u003ctd\u003eBiSS-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface 2, function\u003c\/th\u003e\n\u003ctd\u003eIncremental encoder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronization interface, function\u003c\/th\u003e\n\u003ctd\u003eEncoder emulation A\/B\/Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003e1 MHz maximum output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003e1 MHz maximum output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput switching logic\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLogic input specification\u003c\/th\u003e\n\u003ctd\u003eBased on IEC 61131-2, type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e-3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of high-speed logic inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime resolution of high-speed logic inputs\u003c\/th\u003e\n\u003ctd\u003e1µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24 V DC\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching logic at outputs\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of high-speed switching outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime resolution of high-speed switching outputs\u003c\/th\u003e\n\u003ctd\u003e1µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of floating switching outputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of the floating switching outputs\u003c\/th\u003e\n\u003ctd\u003e50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eDifferential inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003e± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating range of analog inputs\u003c\/th\u003e\n\u003ctd\u003e± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e70kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety function\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety integrity level (SIL)\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\/SIL 3\/SILCL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Level (PL)\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\/category 3, performance level e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic coverage\u003c\/th\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSFF safe failure fraction\u003c\/th\u003e\n\u003ctd\u003e99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware fault tolerance\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of safe 2-pin inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of diagnostic outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769608777883,"sku":"8143167","price":2132.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8143167-1.jpg?v=1781462748"},{"product_id":"8143168","title":"CMMT-AS-C7-11A-P3-MP-S1","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eMounting plate, screwed on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eFree convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e4100g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eLED green\/yellow\/red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eOptional: CDSB operating unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConforms to standard\u003c\/th\u003e\n\u003ctd\u003eEN 61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBased on norm\u003c\/th\u003e\n\u003ctd\u003eEN 50581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKC characters\u003c\/th\u003e\n\u003ctd\u003eKC EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUKCA marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eTo UK instructions for EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertificate issuing authority\u003c\/th\u003e\n\u003ctd\u003eGerman Technical Control Board (TÜV) Rheinland 01\/205\/5640.00\/18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eAbove an ambient temperature of 40 °C, the power must be reduced by 3%\/°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUL-ambient temperature\u003c\/th\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e1% power reduction\/100 m above 1000 m.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurge resistance\u003c\/th\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364 zone III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e48Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current load supply\u003c\/th\u003e\n\u003ctd\u003e9A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current, load supply\u003c\/th\u003e\n\u003ctd\u003e27A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActive PFC\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem voltage to EN 61800-5-1\u003c\/th\u003e\n\u003ctd\u003e300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. short circuit protection of mains\u003c\/th\u003e\n\u003ctd\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains types\u003c\/th\u003e\n\u003ctd\u003eTN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, load supply DC\u003c\/th\u003e\n\u003ctd\u003e560V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad supply permissible range\u003c\/th\u003e\n\u003ctd\u003e± 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e800V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor, integrated\u003c\/th\u003e\n\u003ctd\u003e47Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e13.6kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse energy for braking resistor\u003c\/th\u003e\n\u003ctd\u003e1200Ws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor nominal power (IEC)\u003c\/th\u003e\n\u003ctd\u003e100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor, external\u003c\/th\u003e\n\u003ctd\u003e60Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. continuous output of the external braking resistor (IEC)\u003c\/th\u003e\n\u003ctd\u003e1500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003e± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply without clamping brake\u003c\/th\u003e\n\u003ctd\u003e0.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply with parking brake\u003c\/th\u003e\n\u003ctd\u003e2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply with clamping brake and I\/O\u003c\/th\u003e\n\u003ctd\u003e2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x (0 – input) V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e7A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e21A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e2s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e4000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e12000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. length of motor cable without ext. mains filter\u003c\/th\u003e\n\u003ctd\u003e25m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. output current of holding brake\u003c\/th\u003e\n\u003ctd\u003e1.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. voltage drop from logic supply to brake output\u003c\/th\u003e\n\u003ctd\u003e1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inputs for motor temperature sensor\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController operating mode\u003c\/th\u003e\n\u003ctd\u003eCascade control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMode of operation\u003c\/th\u003e\n\u003ctd\u003eField-oriented regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, function\u003c\/th\u003e\n\u003ctd\u003eParameterization and commissioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, protocol\u003c\/th\u003e\n\u003ctd\u003eTCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eCiA402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eAC1: Adjustable-Speed Drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface, function\u003c\/th\u003e\n\u003ctd\u003eBiSS-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface 2, function\u003c\/th\u003e\n\u003ctd\u003eIncremental encoder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronization interface, function\u003c\/th\u003e\n\u003ctd\u003eEncoder emulation A\/B\/Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003e1 MHz maximum output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003e1 MHz maximum output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput switching logic\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLogic input specification\u003c\/th\u003e\n\u003ctd\u003eBased on IEC 61131-2, type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e-3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of high-speed logic inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime resolution of high-speed logic inputs\u003c\/th\u003e\n\u003ctd\u003e1µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24 V DC\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching logic at outputs\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of high-speed switching outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime resolution of high-speed switching outputs\u003c\/th\u003e\n\u003ctd\u003e1µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of floating switching outputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of the floating switching outputs\u003c\/th\u003e\n\u003ctd\u003e50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eDifferential inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003e± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating range of analog inputs\u003c\/th\u003e\n\u003ctd\u003e± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e70kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety function\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety integrity level (SIL)\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\/SIL 3\/SILCL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Level (PL)\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\/category 3, performance level e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic coverage\u003c\/th\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSFF safe failure fraction\u003c\/th\u003e\n\u003ctd\u003e99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware fault tolerance\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of safe 2-pin inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of diagnostic outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769608810651,"sku":"8143168","price":2809.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8143168-1.jpg?v=1781462750"},{"product_id":"8143169","title":"CMMT-AS-C12-11A-P3-MP-S1","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eMounting plate, screwed on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eFree convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e4100g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003eLED green\/yellow\/red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eOptional: CDSB operating unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConforms to standard\u003c\/th\u003e\n\u003ctd\u003eEN 61800-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBased on norm\u003c\/th\u003e\n\u003ctd\u003eEN 50581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKC characters\u003c\/th\u003e\n\u003ctd\u003eKC EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUKCA marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eTo UK instructions for EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertificate issuing authority\u003c\/th\u003e\n\u003ctd\u003eGerman Technical Control Board (TÜV) Rheinland 01\/205\/5640.00\/18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003eAbove an ambient temperature of 40 °C, the power must be reduced by 3%\/°C.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUL-ambient temperature\u003c\/th\u003e\n\u003ctd\u003e0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 90 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. installation height\u003c\/th\u003e\n\u003ctd\u003e2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. installation height\u003c\/th\u003e\n\u003ctd\u003e1% power reduction\/100 m above 1000 m.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection class\u003c\/th\u003e\n\u003ctd\u003eI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOvervoltage category\u003c\/th\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eContamination level\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSurge resistance\u003c\/th\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364 zone III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage phases\u003c\/th\u003e\n\u003ctd\u003e3-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage AC\u003c\/th\u003e\n\u003ctd\u003e400V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations\u003c\/th\u003e\n\u003ctd\u003e+\/- 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains frequency\u003c\/th\u003e\n\u003ctd\u003e48Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current load supply\u003c\/th\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current, load supply\u003c\/th\u003e\n\u003ctd\u003e45A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eActive PFC\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLine filter\u003c\/th\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem voltage to EN 61800-5-1\u003c\/th\u003e\n\u003ctd\u003e300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. short circuit protection of mains\u003c\/th\u003e\n\u003ctd\u003e10kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains types\u003c\/th\u003e\n\u003ctd\u003eTN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, load supply DC\u003c\/th\u003e\n\u003ctd\u003e560V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLoad supply permissible range\u003c\/th\u003e\n\u003ctd\u003e± 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. DC link voltage\u003c\/th\u003e\n\u003ctd\u003e800V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor, integrated\u003c\/th\u003e\n\u003ctd\u003e47Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse power of braking resistor\u003c\/th\u003e\n\u003ctd\u003e13.6kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePulse energy for braking resistor\u003c\/th\u003e\n\u003ctd\u003e1200Ws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor nominal power (IEC)\u003c\/th\u003e\n\u003ctd\u003e100W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBraking resistor, external\u003c\/th\u003e\n\u003ctd\u003e40Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. continuous output of the external braking resistor (IEC)\u003c\/th\u003e\n\u003ctd\u003e3000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal voltage, logic supply DC\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible range of logic voltage\u003c\/th\u003e\n\u003ctd\u003e± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply without clamping brake\u003c\/th\u003e\n\u003ctd\u003e0.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply with parking brake\u003c\/th\u003e\n\u003ctd\u003e2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current consumption for logic supply with clamping brake and I\/O\u003c\/th\u003e\n\u003ctd\u003e2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput voltage range AC\u003c\/th\u003e\n\u003ctd\u003e3x (0 – input) V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak current per phase, effective\u003c\/th\u003e\n\u003ctd\u003e36A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. peak current duration\u003c\/th\u003e\n\u003ctd\u003e2s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController nominal power\u003c\/th\u003e\n\u003ctd\u003e6000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePeak power\u003c\/th\u003e\n\u003ctd\u003e18000VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutput frequency\u003c\/th\u003e\n\u003ctd\u003e0Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. length of motor cable without ext. mains filter\u003c\/th\u003e\n\u003ctd\u003e25m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. output current of holding brake\u003c\/th\u003e\n\u003ctd\u003e1.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. voltage drop from logic supply to brake output\u003c\/th\u003e\n\u003ctd\u003e1V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of inputs for motor temperature sensor\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eController operating mode\u003c\/th\u003e\n\u003ctd\u003eCascade control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMode of operation\u003c\/th\u003e\n\u003ctd\u003eField-oriented regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, function\u003c\/th\u003e\n\u003ctd\u003eParameterization and commissioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, protocol\u003c\/th\u003e\n\u003ctd\u003eTCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus coupling\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication profile\u003c\/th\u003e\n\u003ctd\u003eCiA402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcess interfacing\u003c\/th\u003e\n\u003ctd\u003eAC1: Adjustable-Speed Drives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface, function\u003c\/th\u003e\n\u003ctd\u003eBiSS-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface 2, function\u003c\/th\u003e\n\u003ctd\u003eIncremental encoder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSynchronization interface, function\u003c\/th\u003e\n\u003ctd\u003eEncoder emulation A\/B\/Z\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface output, characteristics\u003c\/th\u003e\n\u003ctd\u003e1 MHz maximum output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEncoder interface input, characteristics\u003c\/th\u003e\n\u003ctd\u003e1 MHz maximum output frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic inputs\u003c\/th\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput switching logic\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of logic input\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLogic input specification\u003c\/th\u003e\n\u003ctd\u003eBased on IEC 61131-2, type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of logic input\u003c\/th\u003e\n\u003ctd\u003e-3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of high-speed logic inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime resolution of high-speed logic inputs\u003c\/th\u003e\n\u003ctd\u003e1µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of digital logic outputs 24 V DC\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching logic at outputs\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003eFreely configurable in some cases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of digital logic outputs\u003c\/th\u003e\n\u003ctd\u003e20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of high-speed switching outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime resolution of high-speed switching outputs\u003c\/th\u003e\n\u003ctd\u003e1µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of floating switching outputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. current of the floating switching outputs\u003c\/th\u003e\n\u003ctd\u003e50mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of analog setpoint inputs\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristics of setpoint inputs\u003c\/th\u003e\n\u003ctd\u003eDifferential inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork range of setpoint input\u003c\/th\u003e\n\u003ctd\u003e± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating range of analog inputs\u003c\/th\u003e\n\u003ctd\u003e± 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImpedance of setpoint input\u003c\/th\u003e\n\u003ctd\u003e70kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety function\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety integrity level (SIL)\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\/SIL 3\/SILCL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePerformance Level (PL)\u003c\/th\u003e\n\u003ctd\u003eSafe brake control (SBC)\/category 3, performance level e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostic coverage\u003c\/th\u003e\n\u003ctd\u003e97%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSFF safe failure fraction\u003c\/th\u003e\n\u003ctd\u003e99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHardware fault tolerance\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of safe 2-pin inputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNumber of diagnostic outputs\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769608876187,"sku":"8143169","price":3552.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8143169-1.jpg?v=1781462751"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/collections\/8143169-1.jpg?v=1781720818","url":"https:\/\/festopneumatics.com\/collections\/motors-and-servo-drives-servo-drive.oembed","provider":"Festo Pneumatics","version":"1.0","type":"link"}