{"title":"Cteu","description":null,"products":[{"product_id":"2798071","title":"CTEU-EP","description":"bus node CTEU-EP Dimensions W x L x H=40 mm x 91 mm x 50 mm, Fieldbus interface=2x socket, M12x1, 4-pin, D-coded, Diagnosis=(* - Communication error, * - System diagnostics, * - Undervoltage), Configuration support=EDS file, Additional functions=(* AddressConflictDetection (ACD), * - Acyclic data access via \"Explicit Message\", * - EtherNet\/IP Quickconnect, * IP addressing via DHCP, DIL switch, fieldbus or FFT, * Integrated Switch, * - Ringtopologie (DLR), * SNMP, * Start-up parameterisation in normal text via fieldbus, * System status can be represented using process data, * Web servers)\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e40 mm x 91 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e98 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface\u003c\/th\u003e\n\u003ctd\u003e2x socket, M12x1, 4-pin, D-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBaud rate\u003c\/th\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eEtherNet\/IPModbus TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal cycle time\u003c\/th\u003e\n\u003ctd\u003e1 ms per 1 byte of user data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum address volume for inputs\u003c\/th\u003e\n\u003ctd\u003e64 Byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum address volume for outputs\u003c\/th\u003e\n\u003ctd\u003e64 Byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnosis\u003c\/th\u003e\n\u003ctd\u003e'- Communication error- System diagnostics- Undervoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameters configuring\u003c\/th\u003e\n\u003ctd\u003e'- Diagnostic behaviour- Failsafe and idle reaction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional functions\u003c\/th\u003e\n\u003ctd\u003eAddressConflictDetection (ACD)- Acyclic data access via \"Explicit Message\"- EtherNet\/IP QuickconnectIP addressing via DHCP, DIL switch, fieldbus or FFTIntegrated Switch- Ringtopologie (DLR)SNMPStart-up parameterisation in normal text via fieldbusSystem status can be represented using process dataWeb servers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eEDS file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eDIL switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48751934275739,"sku":"2798071","price":654.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/2798071-1.jpg?v=1781284283"},{"product_id":"2149714","title":"CTEU-CP","description":"bus node CTEU-CP Dimensions W x L x H=40 mm x 91 mm x 50 mm, Fieldbus interface=(* Socket M9x0.5, 5-pin, * Plug connector M9x0.5, 5-pin), Diagnosis=(* - Communication error, * - System diagnostics, * - Undervoltage), Configuration support=None, Parameters configuring=(* - Diagnostic behaviour, * - Failsafe response)\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e40 mm x 91 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGrid dimension\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eauf Elektrik-Anschlussplatteauf Elektrik-Anschaltung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e105 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eCPI-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface\u003c\/th\u003e\n\u003ctd\u003eCP installation system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eCPI-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM9x0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e1000 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, function\u003c\/th\u003e\n\u003ctd\u003eBus connection outgoingPower supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection type\u003c\/th\u003e\n\u003ctd\u003ePlug socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48752162078875,"sku":"2149714","price":332.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/2149714-1.jpg?v=1781285193"},{"product_id":"2201471","title":"CTEU-PN","description":"bus node CTEU-PN Dimensions W x L x H=40 mm x 91 mm x 50 mm, Fieldbus interface=2x socket, M12x1, 4-pin, D-coded, Diagnosis=(* - Communication error, * - System diagnostics, * - Undervoltage), Configuration support=GSDML file, Additional functions=(* Conformance class C, * Fast Start Up (FSU), * LLDP, * MRP, * PROFINET IRT, * PROFIenergy, * SNMP, * Shared device, * Web servers)\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e40 mm x 91 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGrid dimension\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eauf Elektrik-Anschlussplatteauf Elektrik-Anschaltung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003ePROFINET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003ePROFINET RT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type of connection\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, D-coded in accordance with EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, electrical isolation\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal cycle time\u003c\/th\u003e\n\u003ctd\u003e1 ms per 1 byte of user data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48752203399323,"sku":"2201471","price":667.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/2201471-1.jpg?v=1781285365"},{"product_id":"1544198","title":"CTEU-CC","description":"\u003cp\u003ebus node CTEU-CC Part number: 1544198\u003c\/p\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48753116610715,"sku":"1544198","price":497.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/1544198-1.jpg?v=1781288728"},{"product_id":"572555","title":"CTEU-AS","description":"bus node CTEU-AS Dimensions W x L x H=40 mm x 91 mm x 50 mm, Fieldbus interface=(* bush, M12x1, 4-pin, A-coded, * Plug, M12x1, 4-pin, A-coded), Diagnosis=(* - Communication error, * - System diagnostics, * - Undervoltage), Configuration support=None, Parameters configuring=(* - Watchdog disable, * - Watchdog enable)\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e40 mm x 91 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGrid dimension\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eauf Elektrik-Anschlussplatteauf Elektrik-Anschaltung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e90 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eAS-Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface\u003c\/th\u003e\n\u003ctd\u003eAS-Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAS-Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, A-coded in accordance with EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, function\u003c\/th\u003e\n\u003ctd\u003eBus connection outgoingPower supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection type\u003c\/th\u003e\n\u003ctd\u003ePlug socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, A-coded in accordance with EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48754944278683,"sku":"572555","price":437.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/572555-1.jpg?v=1781296594"},{"product_id":"572556","title":"CTEU-EC","description":"bus node CTEU-EC Dimensions W x L x H=40 mm x 91 mm x 50 mm, Fieldbus interface=2x socket, M12x1, 4-pin, D-coded, Diagnosis=(* - Communication error, * - System diagnostics, * - Undervoltage), Configuration support=XML file, Additional functions=(* - Acyclic data access via SDO, * Object diagnostics, * Emergency Message, * Modular Device Profile (MDP))\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e40 mm x 91 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGrid dimension\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eauf Elektrik-Anschlussplatteauf Elektrik-Anschaltung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e90 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type of connection\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, D-coded in accordance with EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, electrical isolation\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal cycle time\u003c\/th\u003e\n\u003ctd\u003e1 ms per 1 byte of user data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48754944475291,"sku":"572556","price":575.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/572556-1.jpg?v=1781296596"},{"product_id":"570038","title":"CTEU-CO","description":"bus node CTEU-CO Dimensions W x L x H=40 mm x 91 mm x 50 mm, Fieldbus interface=(* 2x M12x1, 5-pin, * Sub-D socket, 9-pin, * 5-pin terminal strip, * Sub-D plug, for self-assembly), Diagnosis=(* - Communication error, * - System diagnostics, * - Undervoltage), Configuration support=EDS file, Additional functions=(* - Acyclic data access via SDO, * Emergency Message)\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e40 mm x 91 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGrid dimension\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eauf Elektrik-Anschlussplatteauf Elektrik-Anschaltung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e90 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eCANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface\u003c\/th\u003e\n\u003ctd\u003eCAN-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eCANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eSub-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding fieldbus interface\u003c\/th\u003e\n\u003ctd\u003eOptional connection technology with accessories:Optional connection technology with accessories: micro style (plug connector\/socket M12x1 A-coded, 5-pin, degree of protection IP65), open style (terminal strip, 5-pin, degree of protection IP20)Open Style (screw terminal, 5-pin, degree of protection IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, electrical isolation\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e125 kbit\/s250 kbit\/s500 kbit\/s1000 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48754966790299,"sku":"570038","price":437.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/570038-1.jpg?v=1781296695"},{"product_id":"570039","title":"CTEU-DN","description":"bus node CTEU-DN Dimensions W x L x H=40 mm x 91 mm x 50 mm, Fieldbus interface=(* 2x M12x1, 5-pin, * 5-pin terminal strip, * Sub-D plug, for self-assembly, * Sub-D, 9-pin, socket), Diagnosis=(* - Communication error, * - System diagnostics, * - Undervoltage), Configuration support=EDS file, Additional functions=(* - Acyclic data access via \"Explicit Message\", * Quickconnect, * System status can be represented using process data)\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e40 mm x 91 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGrid dimension\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eauf Elektrik-Anschlussplatteauf Elektrik-Anschaltung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e90 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface\u003c\/th\u003e\n\u003ctd\u003eCAN-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eSub-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding fieldbus interface\u003c\/th\u003e\n\u003ctd\u003eOptional connection technology with accessories:Optional connection technology with accessories: micro style (plug connector\/socket M12x1 A-coded, 5-pin, degree of protection IP65), open style (terminal strip, 5-pin, degree of protection IP20)Open Style (screw terminal, 5-pin, degree of protection IP20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, electrical isolation\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e125 kbit\/s250 kbit\/s500 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48754967019675,"sku":"570039","price":437.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/570039-1.jpg?v=1781296697"},{"product_id":"570040","title":"CTEU-PB","description":"bus node CTEU-PB Dimensions W x L x H=40 mm x 91 mm x 50 mm, Fieldbus interface=(* 2x M12x1, 5-pin, B-coded, * Sub-D socket, 9-pin, * Sub-D plug, for self-assembly), Diagnosis=(* - Communication error, * - System diagnostics, * - Undervoltage), Configuration support=Device database file, Additional functions=(* Emergency Message, * System status via diagnostic test)\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e40 mm x 91 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGrid dimension\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eauf Elektrik-Anschlussplatteauf Elektrik-Anschaltung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e90 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eProfibus DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eSub-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding fieldbus interface\u003c\/th\u003e\n\u003ctd\u003eOptional connection technology with accessories:Plug connector\/socket M12x1 B-coded, 5-pin, degree of protection IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, electrical isolation\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e9,6 kbit\/s19,2 kbit\/s93,75 kbit\/s187,5 kbit\/s500 kbit\/s1,5 Mbit\/s12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48754967249051,"sku":"570040","price":437.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/570040-1.jpg?v=1781296699"},{"product_id":"8087559","title":"CTEU-VN","description":"","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767287132315,"sku":"8087559","price":654.26,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8087559-1.jpg?v=1781403020"},{"product_id":"8107588","title":"CTEU-PB-EX1C","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e Dimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e40 mm x 91 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Width dimension\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Type of mounting\u003c\/th\u003e\n\u003ctd\u003eOn electrical interface On electrical sub-base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Product weight\u003c\/th\u003e\n\u003ctd\u003e90 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Protocol\u003c\/th\u003e\n\u003ctd\u003eProfibus DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eSub-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995638\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Note on fieldbus interface\u003c\/th\u003e\n\u003ctd\u003ePlug\/socket M12x1 B-coded, 5-pin, degree of protection: IP65 Optional connection technology with accessories:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e1.5 Mbit\/s 12 Mbit\/s 187.5 kbit\/s 19.2 kbit\/s 500 kbit\/s 9.6 kbit\/s 93.75 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Internal cycle time\u003c\/th\u003e\n\u003ctd\u003e1 ms per 1 byte of user data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e16 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e16 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Power supply, function\u003c\/th\u003e\n\u003ctd\u003eElectronics and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Power supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Power supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, A-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Power supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Power supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995383\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Diagnostics\u003c\/th\u003e\n\u003ctd\u003eCommunication error System diagnostics Undervoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Parameterization\u003c\/th\u003e\n\u003ctd\u003eDiagnostic behavior Fail-safe response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Additional functions\u003c\/th\u003e\n\u003ctd\u003eEmergency message System status via diagnostic test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Configuration support\u003c\/th\u003e\n\u003ctd\u003eGSD file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Control elements\u003c\/th\u003e\n\u003ctd\u003eDIL switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e LED display (product-specific)\u003c\/th\u003e\n\u003ctd\u003ePS: operating voltage for electronics and load supply X1: module system status at I-Port 1 X2: module system status at I-Port 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e LED display (bus-specific)\u003c\/th\u003e\n\u003ctd\u003eBF: bus fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e DC operating voltage range\u003c\/th\u003e\n\u003ctd\u003e 18 V ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Intrinsic current consumption at nominal operating voltage\u003c\/th\u003e\n\u003ctd\u003eTyp. 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. power supply\u003c\/th\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Certification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Corrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e CE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Storage temperature\u003c\/th\u003e\n\u003ctd\u003e -20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65 IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Note on degree of protection\u003c\/th\u003e\n\u003ctd\u003eIn mounted state Unused connections sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Ambient temperature\u003c\/th\u003e\n\u003ctd\u003e -5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Housing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Note on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substances RoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769480327323,"sku":"8107588","price":553.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8107588-1.jpg?v=1781461214"},{"product_id":"8107589","title":"CTEU-PN-EX1C","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e Dimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e40 mm x 91 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Width dimension\u003c\/th\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Type of mounting\u003c\/th\u003e\n\u003ctd\u003eOn electrical interface On electrical sub-base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Product weight\u003c\/th\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Protocol\u003c\/th\u003e\n\u003ctd\u003ePROFINET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003ePROFINET RT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, D-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Internal cycle time\u003c\/th\u003e\n\u003ctd\u003e1 ms per 1 byte of user data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Power supply, function\u003c\/th\u003e\n\u003ctd\u003eElectronics and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Power supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Power supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, A-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Power supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Power supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e00995383\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Diagnostics\u003c\/th\u003e\n\u003ctd\u003eCommunication error System diagnostics Undervoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Additional functions\u003c\/th\u003e\n\u003ctd\u003eConformance class C Fast start-up (FSU) LLDP MRP PROFINET IRT PROFIenergy SNMP Shared device Web server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Configuration support\u003c\/th\u003e\n\u003ctd\u003eGSDML file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e LED display (product-specific)\u003c\/th\u003e\n\u003ctd\u003ePS: operating voltage for electronics and load supply X1: module system status at I-Port 1 X2: module system status at I-Port 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e LED display (bus-specific)\u003c\/th\u003e\n\u003ctd\u003eNF: network fault TP1: network active port 1 TP2: network active, port 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e DC operating voltage range\u003c\/th\u003e\n\u003ctd\u003e 18 V ... 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Intrinsic current consumption at nominal operating voltage\u003c\/th\u003e\n\u003ctd\u003eTyp. 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. power supply\u003c\/th\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Certification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Corrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e CE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Storage temperature\u003c\/th\u003e\n\u003ctd\u003e -20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65 IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Note on degree of protection\u003c\/th\u003e\n\u003ctd\u003eIn mounted state Unused connections sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Ambient temperature\u003c\/th\u003e\n\u003ctd\u003e -5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Housing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Note on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substances RoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769480458395,"sku":"8107589","price":774.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8107589-1.jpg?v=1781461216"},{"product_id":"8107591","title":"CTEU-EP-EX1C","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e40 mm x 91 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e98g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLABS (PWIS) conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364 zone III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUKCA marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eTo UK instructions for EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertificate issuing authority\u003c\/th\u003e\n\u003ctd\u003eUL E239998\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED display (product-specific)\u003c\/th\u003e\n\u003ctd\u003ePS: operating voltage for electronics and load supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED display (bus-specific)\u003c\/th\u003e\n\u003ctd\u003eNS: network status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics\u003c\/th\u003e\n\u003ctd\u003eCommunication error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eDIL switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface\u003c\/th\u003e\n\u003ctd\u003e2x socket, M12x1, 4-pin, D-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e64byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e64byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization\u003c\/th\u003e\n\u003ctd\u003eDiagnostic behavior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBaud rate\u003c\/th\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal cycle time\u003c\/th\u003e\n\u003ctd\u003e1 ms per 1 byte of user data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eEDS file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional functions\u003c\/th\u003e\n\u003ctd\u003eAddressConflictDetection (ACD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC operating voltage range\u003c\/th\u003e\n\u003ctd\u003e18V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e4A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage\u003c\/th\u003e\n\u003ctd\u003eTyp. 65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769645740187,"sku":"8107591","price":710.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8107591-1.jpg?v=1781464010"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/collections\/8107591-1.jpg?v=1781720656","url":"https:\/\/festopneumatics.com\/collections\/electrical-peripherals-cteu.oembed","provider":"Festo Pneumatics","version":"1.0","type":"link"}