{"title":"Cpx ap i","description":null,"products":[{"product_id":"8086600","title":"CPX-AP-I-8DI-M8-3P","description":"\u003cbr\u003e\u003cbr\u003e\u003ca id=\"festo-fast-shipping\" href=\"#festo-fast\"\u003e\u003cimg src=\"https:\/\/www.coastpneumatics.com\/wp-content\/uploads\/2025\/09\/fast-logo-300x137.webp\" alt=\"\" width=\"153\" height=\"70\"\u003e\u003c\/a\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767286247579,"sku":"8086600","price":218.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8086600-1.jpg?v=1781402973"},{"product_id":"8086601","title":"CPX-AP-I-4DI4DO-M8-3P","description":"\u003cbr\u003e\u003cbr\u003e\u003ca id=\"festo-fast-shipping\" href=\"#festo-fast\"\u003e\u003cimg src=\"https:\/\/www.coastpneumatics.com\/wp-content\/uploads\/2025\/09\/fast-logo-300x137.webp\" alt=\"\" width=\"153\" height=\"70\"\u003e\u003c\/a\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767286280347,"sku":"8086601","price":262.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8086601-1.jpg?v=1781402975"},{"product_id":"8086602","title":"CPX-AP-I-8DI-M12-5P","description":"\u003cbr\u003e\u003cbr\u003e\u003ca id=\"festo-fast-shipping\" href=\"#festo-fast\"\u003e\u003cimg src=\"https:\/\/www.coastpneumatics.com\/wp-content\/uploads\/2025\/09\/fast-logo-300x137.webp\" alt=\"\" width=\"153\" height=\"70\"\u003e\u003c\/a\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767286313115,"sku":"8086602","price":218.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8086602-1.jpg?v=1781402976"},{"product_id":"8086603","title":"CPX-AP-I-4DI4DO-M12-5P","description":"\u003cbr\u003e\u003cbr\u003e\u003ca id=\"festo-fast-shipping\" href=\"#festo-fast\"\u003e\u003cimg src=\"https:\/\/www.coastpneumatics.com\/wp-content\/uploads\/2025\/09\/fast-logo-300x137.webp\" alt=\"\" width=\"153\" height=\"70\"\u003e\u003c\/a\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767286345883,"sku":"8086603","price":262.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8086603-1.jpg?v=1781402978"},{"product_id":"8086607","title":"CPX-AP-I-PN-M12","description":"\u003cbr\u003e\u003cbr\u003e\u003ca id=\"festo-fast-shipping\" href=\"#festo-fast\"\u003e\u003cimg src=\"https:\/\/www.coastpneumatics.com\/wp-content\/uploads\/2025\/09\/fast-logo-300x137.webp\" alt=\"\" width=\"153\" height=\"70\"\u003e\u003c\/a\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767286378651,"sku":"8086607","price":655.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8086607-1.jpg?v=1781402980"},{"product_id":"8086604","title":"CPX-AP-I-4IOL-M12","description":"\u003cbr\u003e\u003cbr\u003e\u003ca id=\"festo-fast-shipping\" href=\"#festo-fast\"\u003e\u003cimg src=\"https:\/\/www.coastpneumatics.com\/wp-content\/uploads\/2025\/09\/fast-logo-300x137.webp\" alt=\"\" width=\"153\" height=\"70\"\u003e\u003c\/a\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767912706203,"sku":"8086604","price":437.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8086604-1.jpg?v=1781452725"},{"product_id":"8086605","title":"CPX-AP-I-4DI-M8-3P","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e30 mm x 102.5 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKC characters\u003c\/th\u003e\n\u003ctd\u003eKC EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnose per internal communication\u003c\/th\u003e\n\u003ctd\u003eShort circuit\/overload in sensor supplyElectronics\/sensors overvoltageElectronics\/sensors undervoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e2 x 4 A (external fuse required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on degree of protection\u003c\/th\u003e\n\u003ctd\u003eUnused connections sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection inputs (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, D-coded as per EN 61076-2-114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, A-coded as per EN 61076-2-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 32 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, function\u003c\/th\u003e\n\u003ctd\u003eSystem communication XF10 IN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e30 m inputs50 m system communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, function\u003c\/th\u003e\n\u003ctd\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP-COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDigital inputs, electrical isolation of input - internal communication\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eDiagnostics per moduleStatus per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation of inputs between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, connection type\u003c\/th\u003e\n\u003ctd\u003e4x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, shielding\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical input connection, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, A-coded as per EN 61076-2-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection, input, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of inputs\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current of inputs per module\u003c\/th\u003e\n\u003ctd\u003e0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies requiredNote voltage drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-AP-I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput debounce time\u003c\/th\u003e\n\u003ctd\u003e0.1 ms3 ms10 ms20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching level\u003c\/th\u003e\n\u003ctd\u003eSignal 0: \u0026lt;= 5 VSignal 1: \u0026gt;= 11 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C ... 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e81 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput characteristics\u003c\/th\u003e\n\u003ctd\u003eAs per IEC 61131-2, type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput switching logic\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)2-wire sensors as per IEC 61131-23-wire sensors as per IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePAPCDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48768186613915,"sku":"8086605","price":174.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8086605-1.jpg?v=1781454655"},{"product_id":"8086606","title":"CPX-AP-I-4AI-U-I-RTD-M12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e30 mm x 170 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKC characters\u003c\/th\u003e\n\u003ctd\u003eKC EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnose per internal communication\u003c\/th\u003e\n\u003ctd\u003eWire breakModule errorShort circuit\/overload in sensor supplyParameter errorParameterization errorOverload at analog inputsUpper limit value violatedUnderflow\/overflowLower limit value not complied with\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e2 x 4 A (external fuse required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on degree of protection\u003c\/th\u003e\n\u003ctd\u003eUnused connections sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection inputs (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, D-coded as per EN 61076-2-114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, A-coded as per EN 61076-2-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, A-coded as per EN 61076-2-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 38 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, function\u003c\/th\u003e\n\u003ctd\u003eSystem communication XF10 IN \/ XF20 OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e30 m inputs50 m system communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, function\u003c\/th\u003e\n\u003ctd\u003eAnalog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP-COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDigital inputs, electrical isolation of input - internal communication\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eDiagnostics per moduleStatus per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation of inputs between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, connection type\u003c\/th\u003e\n\u003ctd\u003e4x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, shielding\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, function\u003c\/th\u003e\n\u003ctd\u003eOutgoing electronics\/sensors and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical input connection, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1 A-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection, input, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of inputs\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current of inputs per module\u003c\/th\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies requiredNote voltage drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection, input, note on connection technology\u003c\/th\u003e\n\u003ctd\u003eTo achieve the technical specifications, the opposite side is shielded and must be designed with contact surfaces made from gold.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBasic error limit at 25°C\u003c\/th\u003e\n\u003ctd\u003e±0.1 % for voltage±0.1 % for electrical current±0.2 % for resistor±0.4 % for temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured variable\u003c\/th\u003e\n\u003ctd\u003eVoltageCurrentTemperatureResistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData format\u003c\/th\u003e\n\u003ctd\u003e15 bit + signLinear scaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepetition accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.025 % at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal range\u003c\/th\u003e\n\u003ctd\u003e-10 - 10 V-5 - 5 V0 - 10 V0 - 20 mA0 - 500 Ω1 - 5 V4 - 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating error limit related to the ambient temperature range\u003c\/th\u003e\n\u003ctd\u003e±0.15 % for voltage±0.15 % for electrical current±0.35 % for resistor±0.9 % for temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-AP-I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C ... 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e166 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePAPCDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48768187138203,"sku":"8086606","price":546.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8086606-1.jpg?v=1781454656"},{"product_id":"8086608","title":"CPX-AP-I-PB-M12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e45 mm x 170 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKC characters\u003c\/th\u003e\n\u003ctd\u003eKC EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, B-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e2 x 4 A (external fuse required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on degree of protection\u003c\/th\u003e\n\u003ctd\u003eUnused connections sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, D-coded as per EN 61076-2-114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, A-coded as per EN 61076-2-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eIncoming bus connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage load\u003c\/th\u003e\n\u003ctd\u003eTypically 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, A-coded as per EN 61076-2-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eLoad switch-offLoad overvoltageLoad undervoltageElectronics\/sensors overvoltageElectronics\/sensors undervoltageAPDD invalidCommunication with AP module interrupted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, function\u003c\/th\u003e\n\u003ctd\u003eSystem communication XF20 OUT \/ XF21 OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS DP-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eGSD file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e50 m system communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP-COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e9.6 kbit\/s19.2 kbit\/s93.75 kbit\/s187.5 kbit\/s500 kbit\/s1.5 Mbit\/s3 Mbit\/s6 Mbit\/s12 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eBuffer error LED (BF)Diagnostics per modulePower supply for electronics\/sensorsLoad power supplySystem diagnosticsMaintenance required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations load\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, shielding\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, function\u003c\/th\u003e\n\u003ctd\u003eOutgoing electronics\/sensors and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e244 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e244 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies requiredNote voltage drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, protocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS DP-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, type\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, B-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, transmission rate\u003c\/th\u003e\n\u003ctd\u003e1.5 mbps12 mbps187.5 kbps19.2 kbps3 mbps500 kbps6 mbps9.6 kbps93.75 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on fieldbus interface\u003c\/th\u003e\n\u003ctd\u003eTerminating resistor on socket possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-AP-I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C ... 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePAPCDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48768187367579,"sku":"8086608","price":655.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8086608-1.jpg?v=1781454658"},{"product_id":"8086609","title":"CPX-AP-I-EC-M12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e45 mm x 170 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKC characters\u003c\/th\u003e\n\u003ctd\u003eKC EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, D-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnose per internal communication\u003c\/th\u003e\n\u003ctd\u003eModule errorOutput short circuit\/overloadShort circuit\/overload in sensor supplyLoad supply undervoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e2 x 4 A (external fuse required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on degree of protection\u003c\/th\u003e\n\u003ctd\u003eUnused connections sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, D-coded as per EN 61076-2-114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, A-coded as per EN 61076-2-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. cable length\u003c\/th\u003e\n\u003ctd\u003ePower supply according to nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage load\u003c\/th\u003e\n\u003ctd\u003eTypically 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, A-coded as per EN 61076-2-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eLoad switch-offLoad overvoltageLoad undervoltageElectronics\/sensors overvoltageElectronics\/sensors undervoltageAPDD invalidCommunication with AP module interrupted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 90 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, function\u003c\/th\u003e\n\u003ctd\u003eSystem communication XF20 OUT \/ XF21 OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eESI file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e50 m system communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP-COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eDiagnostics per moduleEtherCAT RUNPower supply for electronics\/sensorsLoad power supplySystem diagnosticsMaintenance required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations load\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, shielding\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, function\u003c\/th\u003e\n\u003ctd\u003eOutgoing electronics\/sensors and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e2048 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e2048 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies requiredNote voltage drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-AP-I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C ... 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e186 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePAPCDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48768187662491,"sku":"8086609","price":655.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8086609-1.jpg?v=1781454660"},{"product_id":"8086610","title":"CPX-AP-I-EP-M12","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e45 mm x 170 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKC characters\u003c\/th\u003e\n\u003ctd\u003eKC EMC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1, D-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnose per internal communication\u003c\/th\u003e\n\u003ctd\u003eModule errorOutput short circuit\/overloadShort circuit\/overload in sensor supplyLoad supply undervoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e2 x 4 A (external fuse required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on degree of protection\u003c\/th\u003e\n\u003ctd\u003eUnused connections sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, D-coded as per EN 61076-2-114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, A-coded as per EN 61076-2-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eIncoming electronics\/sensors and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on max. cable length\u003c\/th\u003e\n\u003ctd\u003ePower supply according to nominal voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage load\u003c\/th\u003e\n\u003ctd\u003eTypically 5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, connection technology\u003c\/th\u003e\n\u003ctd\u003eM8x1, A-coded as per EN 61076-2-104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eLoad switch-offLoad overvoltageLoad undervoltageElectronics\/sensors overvoltageElectronics\/sensors undervoltageAPDD invalidCommunication with AP module interrupted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e5 - 95 %Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 90 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, function\u003c\/th\u003e\n\u003ctd\u003eSystem communication XF20 OUT \/ XF21 OUT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eEDS file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003e50 m system communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, protocol\u003c\/th\u003e\n\u003ctd\u003eAP-COM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eDiagnostics per moduleNetwork status Ethernet\/IPPower supply for electronics\/sensorsLoad power supplySystem diagnosticsMaintenance required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations load\u003c\/th\u003e\n\u003ctd\u003e± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, shielding\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, function\u003c\/th\u003e\n\u003ctd\u003eOutgoing electronics\/sensors and load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e1324 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage forwarding, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e1324 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication interface, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote regarding operating voltage\u003c\/th\u003e\n\u003ctd\u003eSELV\/PELV fixed power supplies requiredNote voltage drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-AP-I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReverse polarity protection\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e1 - Low corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-40 °C ... 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e194 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePAPCDie-cast zinc, nickel-plated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48768187957403,"sku":"8086610","price":655.72,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8086610-1.jpg?v=1781454662"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/collections\/8086610-1.jpg?v=1781720654","url":"https:\/\/festopneumatics.com\/collections\/electrical-peripherals-cpx-ap-i.oembed","provider":"Festo Pneumatics","version":"1.0","type":"link"}