{"title":"CPX-E","description":null,"products":[{"product_id":"4080491","title":"CPX-E-8DO","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e18.9 mm x 76.6 mm x 124.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations load\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage load\u003c\/th\u003e\n\u003ctd\u003eTypically 34 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eModule errorLoad supply undervoltageOutput short circuit\/overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, function\u003c\/th\u003e\n\u003ctd\u003eDigital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, connection type\u003c\/th\u003e\n\u003ctd\u003e4x terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for output, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for output, information on conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eResponse to short circuit\/overloadOutput short circuit diagnosticsLoad supply undervoltage diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel parameters\u003c\/th\u003e\n\u003ctd\u003eForcing channel x\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eFaults per channelStatus per channelFaults per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical output connection, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of outputs\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current of outputs per module\u003c\/th\u003e\n\u003ctd\u003e0.166666666666667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003eNon-condensing95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e93 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e1 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharacteristic curve outputs\u003c\/th\u003e\n\u003ctd\u003eAs per IEC 61131-2, type 0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching logic at outputs\u003c\/th\u003e\n\u003ctd\u003ePNP (positive switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766954995867,"sku":"4080491","price":214.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4080491-1.jpg?v=1781399008"},{"product_id":"4080492","title":"CPX-E-16DI","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e18.9 mm x 76.6 mm x 124.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, function\u003c\/th\u003e\n\u003ctd\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 15 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input, information on conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995843\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eSensor supply short circuit\/overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical input connection, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, connection type\u003c\/th\u003e\n\u003ctd\u003e8x terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eSignal extension timeResponse to short circuit\/overloadSensor supply short circuit diagnosticsInput debounce time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel parameters\u003c\/th\u003e\n\u003ctd\u003eSignal extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eStatus per channelFaults per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection, input, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input, conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of inputs\u003c\/th\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput debounce time\u003c\/th\u003e\n\u003ctd\u003e10 ms0.1 ms3 ms20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching level\u003c\/th\u003e\n\u003ctd\u003eSignal 1: \u0026gt;= 11 VSignal 0: \u0026lt;= 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003eNon-condensing95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e102 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e2 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput characteristics\u003c\/th\u003e\n\u003ctd\u003eAs per IEC 61131-2, type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput switching logic\u003c\/th\u003e\n\u003ctd\u003e3-wire sensors as per IEC 61131-2PNP (positive switching)2-wire sensors as per IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766957879451,"sku":"4080492","price":262.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4080492-1.jpg?v=1781399010"},{"product_id":"4080493","title":"CPX-E-4AI-U-I","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e18.9 mm x 76.6 mm x 124.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, function\u003c\/th\u003e\n\u003ctd\u003eAnalog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input, information on conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eLower limit value not complied withParameter errorParameterization errorSensor supply short circuit\/overloadUnderflow\/overflowUpper limit value violatedWire breakOverload at analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical input connection, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal range\u003c\/th\u003e\n\u003ctd\u003e-20 - 20 mA0 - 20 mA0 - 10 V-5 - 5 V1 - 5 V-10 - 10 V4 - 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, connection type\u003c\/th\u003e\n\u003ctd\u003e4x terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eAnalog input overload diagnosticsResponse to analog input overloadAnalog input data formatSensor supply short circuit diagnosticsLimit monitoring hysteresisResponse to short circuit\/overloadDeactivate sensor supplyParameterization error diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel parameters\u003c\/th\u003e\n\u003ctd\u003eWire break diagnosticsSignal range per channelUpper limit diagnosticsLower diagnostic limitUnderflow\/overflow diagnosticsParameter error diagnosticsSmoothing factorLower\/upper limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eFaults per channelFaults per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input 2, function\u003c\/th\u003e\n\u003ctd\u003eFunctional ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input 2, connection type\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input 2, information on conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical input 2 connection, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input 2, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995842\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection, input, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection, input 2, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input 2, conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of inputs\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured variable\u003c\/th\u003e\n\u003ctd\u003eVoltageCurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepetition accuracy\u003c\/th\u003e\n\u003ctd\u003eÂ±0.1 % at 25 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating error limit related to the ambient temperature range\u003c\/th\u003e\n\u003ctd\u003e+\/- 0.3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBasic error limit at 25Â°C\u003c\/th\u003e\n\u003ctd\u003e+\/- 0.2 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current of inputs per module\u003c\/th\u003e\n\u003ctd\u003e1.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003eNon-condensing95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e96 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e8 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData format\u003c\/th\u003e\n\u003ctd\u003e15 bit + signLinear scaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003eShielded30 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantContains paint-wetting impairment substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766961090715,"sku":"4080493","price":546.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4080493-1.jpg?v=1781399012"},{"product_id":"4080494","title":"CPX-E-4AO-U-I","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e18.9 mm x 76.6 mm x 124.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003e2x terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations load\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage load\u003c\/th\u003e\n\u003ctd\u003eTypically 15 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eNominal range was exceededParameterization errorLoad supply undervoltageGeneral errorActuator supply short circuit\/overloadAnalog output short circuit\/overloadNominal range not reached\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, function\u003c\/th\u003e\n\u003ctd\u003eAnalog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, connection type\u003c\/th\u003e\n\u003ctd\u003e4x terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for output, information on conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal range\u003c\/th\u003e\n\u003ctd\u003e4 - 20 mA0 - 10 V-10 - 10 V-20 - 20 mA0 - 20 mA-5 - 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eParameterization error diagnosticsDeactivate actuator supplyActuator supply short circuit diagnosticsResponse to actuator supply short circuit\/overloadAnalog output data formatLoad supply undervoltage diagnosticsResponse to analog output short circuit\/overload\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel parameters\u003c\/th\u003e\n\u003ctd\u003eForcing channel xEnable overload\/short circuit diagnosticsSignal range per channelEnable parameterization error diagnosticsEnable wire break\/idling diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eFaults per channelFaults per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for output 2, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995842\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for output 2, Information on conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output 2, connection type\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output 2, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical output connection, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC load\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical output connection 2, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for output, conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for output 2, conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of outputs\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured variable\u003c\/th\u003e\n\u003ctd\u003eVoltageCurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepetition accuracy\u003c\/th\u003e\n\u003ctd\u003eÂ±0.05 % at 25 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating error limit related to the ambient temperature range\u003c\/th\u003e\n\u003ctd\u003e+\/- 0.3 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBasic error limit at 25Â°C\u003c\/th\u003e\n\u003ctd\u003e+\/- 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current of outputs per module\u003c\/th\u003e\n\u003ctd\u003e0.0833333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e95 %Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e96 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e8 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData format\u003c\/th\u003e\n\u003ctd\u003e15 bit + signLinear scaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. cable length\u003c\/th\u003e\n\u003ctd\u003eShielded30 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766964367515,"sku":"4080494","price":546.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4080494-1.jpg?v=1781399014"},{"product_id":"4080495","title":"CPX-E-4IOL","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e18.9 mm x 76.6 mm x 124.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations load\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 50 Â°C for horizontal installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage load\u003c\/th\u003e\n\u003ctd\u003eTypically 15 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eWire breakUnderflow\/overflowShort circuitGeneral errorParameter errorModule errorDevice missing\/failedUndervoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eActuator supply short circuit diagnosticsResponse to short circuit\/overloadDeactivate sensor supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel parameters\u003c\/th\u003e\n\u003ctd\u003eForcing channel xCycle timeChannel statusDeactivate actuator supplyChannel modeDevice fault code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eFaults per moduleStatus per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection, IO-LinkÂ®, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectric IO-LinkÂ® connection, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995843\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical IO-LinkÂ® connection, connection type\u003c\/th\u003e\n\u003ctd\u003e4x terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIO-LinkÂ®, communication\u003c\/th\u003e\n\u003ctd\u003eC\/Q LED green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIO-LinkÂ® electrical connection, information on conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical IO-LinkÂ® connection, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIO-LinkÂ® electrical connection, conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse, load per channelInternal electronic fuse, sensor per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e95 %Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e96 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtocol\u003c\/th\u003e\n\u003ctd\u003eIO-LinkÂ®\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIO-LinkÂ®, protocol version\u003c\/th\u003e\n\u003ctd\u003eMaster V 1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIO-LinkÂ®, communication mode\u003c\/th\u003e\n\u003ctd\u003eSIO, COM1 (4.8 kBd), COM2 (38.4 kBd), COM3 (230.4 kBd)Configurable via software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIO-LinkÂ®, port class\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIO-LinkÂ®, number of ports\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIO-LinkÂ®, process data width OUT\u003c\/th\u003e\n\u003ctd\u003e8â€“32 bytes parameterizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIO-LinkÂ®, process data width IN\u003c\/th\u003e\n\u003ctd\u003e8â€“32 bytes parameterizable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIO-LinkÂ®, minimum cycle time\u003c\/th\u003e\n\u003ctd\u003eDepends on minimally supported cycle time of connected IO-LinkÂ® device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766967316635,"sku":"4080495","price":437.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4080495-1.jpg?v=1781399016"},{"product_id":"4080496","title":"CPX-E-PB","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e42.2 mm x 125.8 mm x 76.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on fieldbus interface\u003c\/th\u003e\n\u003ctd\u003eOptional connection technology with accessories:Plug\/socket M12x1 B-coded, 5-pin, degree of protection: IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eUSB 2.0 type B, mini\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eParameterization errorWire breakUndervoltageLower limit value not complied withUpper limit value violatedRequested function not supportedBuffer overflowNot ready for data exchangeTransmission errorWatchdog\/I\/O statusShort circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995638\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eElectronics and sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995868\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService interface, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem parameter\u003c\/th\u003e\n\u003ctd\u003eForce modeSystem startFail-safe responseDiagnostic memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eSub-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService interface, function\u003c\/th\u003e\n\u003ctd\u003eDiagnostics and parameterization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eForce modeSystem faultBus errorPower supply for electronics\/sensorsLoad power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eService interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for outputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eGSD file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eDIL switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e0.333333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003eNon-condensing95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e145 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on outputs\u003c\/th\u003e\n\u003ctd\u003e64 bytes with status bits62 bytes with I\/O diagnostic interface64 bytes without diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on inputs\u003c\/th\u003e\n\u003ctd\u003e63 bytes with status bits62 bytes with I\/O diagnostic interface64 bytes without diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e3 Mbit\/s19.2 kbit\/s9.6 kbit\/s500 kbit\/s1.5 Mbit\/s187.5 kbit\/s12 Mbit\/s93.75 kbit\/s6 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003ePROFIBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766968791195,"sku":"4080496","price":612.01,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4080496-1.jpg?v=1781399018"},{"product_id":"4080497","title":"CPX-E-PN","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e42.2 mm x 125.8 mm x 76.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eUndervoltageParameterization errorPROFIsafe addresses differentUpper limit value violatedLower limit value not complied withWire breakOver temperatureShort circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eElectronics and sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem parameter\u003c\/th\u003e\n\u003ctd\u003eDiagnostic memoryFail-safe responseSystem startForce mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003ePROFINET RTPROFINET IRT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eChannel alarms for undervoltageChannel alarm bundlingUndervoltage diagnosticsAnalog module process value representation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eSystem faultLoad power supplyNetwork errorPower supply for electronics\/sensorsMaintenance requiredNetwork status, port 1Network status, port 2Force mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eGSDML file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e0.333333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e95 %Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e145 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on outputs\u003c\/th\u003e\n\u003ctd\u003e62 bytes with I\/O diagnostic interface64 bytes without diagnostics64 bytes with status bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on inputs\u003c\/th\u003e\n\u003ctd\u003e62 bytes with I\/O diagnostic interface64 bytes without diagnostics62 bytes with status bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantContains paint-wetting impairment substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766971707547,"sku":"4080497","price":765.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4080497-1.jpg?v=1781399020"},{"product_id":"4080498","title":"CPX-E-EC","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e42.2 mm x 125.8 mm x 76.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 64 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eLower limit value not complied withShort circuitOver temperatureUpper limit value violatedWire breakUndervoltageParameterization error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eElectronics and sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem parameter\u003c\/th\u003e\n\u003ctd\u003eDiagnostic memoryForce modeFail-safe responseSystem start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eUndervoltage diagnosticsChannel alarms for undervoltageChannel alarm bundling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003ePower supply for electronics\/sensorsModifyEtherCAT RUNSystem faultLoad power supplyEtherCAT errorConnection status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eESI file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e0.333333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003eNon-condensing95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e145 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on outputs\u003c\/th\u003e\n\u003ctd\u003e62 bytes with I\/O diagnostic interface64 bytes without diagnostics64 bytes with status bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on inputs\u003c\/th\u003e\n\u003ctd\u003e64 bytes without diagnostics62 bytes with I\/O diagnostic interface63 bytes with status bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEtherCAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766974263451,"sku":"4080498","price":765.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4080498-1.jpg?v=1781399023"},{"product_id":"4080499","title":"CPX-E-EP","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e42.2 mm x 125.8 mm x 76.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eLower limit value not complied withParameterization errorUndervoltageOver temperatureShort circuitUpper limit value violatedWire break\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eElectronics and sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem parameter\u003c\/th\u003e\n\u003ctd\u003eDiagnostic memoryFail-safe responseSystem startForce modeIdle response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eModbusÂ®\/TCPEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eChannel alarm bundlingChannel alarms for undervoltageUndervoltage diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eNetwork statusPower supply for electronics\/sensorsLoad power supplyConnection statusSystem faultModifyModule status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eEDS file\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e0.333333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003eNon-condensing95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e145 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on outputs\u003c\/th\u003e\n\u003ctd\u003e62 bytes with I\/O diagnostic interface64 bytes with status bits64 bytes without diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInformation on inputs\u003c\/th\u003e\n\u003ctd\u003e64 bytes without diagnostics63 bytes with status bits62 bytes with I\/O diagnostic interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantContains paint-wetting impairment substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48766974460059,"sku":"4080499","price":765.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4080499-1.jpg?v=1781399025"},{"product_id":"4252741","title":"CPX-E-CEC-C1-PN","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e75.9 mm x 124.3 mm x 82.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEasyIPTCP\/IPModbusÂ® TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage medium\u003c\/th\u003e\n\u003ctd\u003eUSB memory stick \u0026lt;= 32 GBMicro SD \u0026lt;= 32 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e10 Mbit\/s100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eElectronics and sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, function\u003c\/th\u003e\n\u003ctd\u003eSwitchDiagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem parameter\u003c\/th\u003e\n\u003ctd\u003eSystem startDiagnostic memoryFail-safe response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003ePROFINET IO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eUndervoltage diagnosticsAnalog module process value representationChannel alarm bundlingChannel alarms for undervoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eNetwork errorEtherCAT network statusMaintenance requiredRunLoad power supplyNetwork status, port 2System faultPower supply for electronics\/sensorsEngineering port 2 network statusForce modeNetwork status, port 1Network status, engineering port 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for outputs\u003c\/th\u003e\n\u003ctd\u003e512 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for inputs\u003c\/th\u003e\n\u003ctd\u003e512 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU data\u003c\/th\u003e\n\u003ctd\u003eDual core 766 MHz512 MB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eGSDML fileCODESYS V3Operator unit CDSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional functions\u003c\/th\u003e\n\u003ctd\u003eCODESYS V3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eDIL switch for RUN\/STOPOptional: CDSB operating unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcessing time\u003c\/th\u003e\n\u003ctd\u003eApprox. 200 Âµs\/1 k instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP address setting\u003c\/th\u003e\n\u003ctd\u003eVia CODESYSOptional: via CDSB operating unitDHCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction blocks\u003c\/th\u003e\n\u003ctd\u003eand othersRead CPX-E module diagnosticsCopying of CPX-E diagnostic traceCPX-E diagnostic status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e0.333333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlag\u003c\/th\u003e\n\u003ctd\u003e120 kB remanent dataCODESYS variable concept\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgramming software\u003c\/th\u003e\n\u003ctd\u003eCODESYS provided by Festo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgram memory\u003c\/th\u003e\n\u003ctd\u003e12 MB user program\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003eNon-condensing95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003ec UL us - Listed (OL)RCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e288 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767067029659,"sku":"4252741","price":2063.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4252741-1.jpg?v=1781399128"},{"product_id":"4252742","title":"CPX-E-CEC-C1-EP","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e75.9 mm x 124.3 mm x 82.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEasyIPModbusÂ® TCPTCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage medium\u003c\/th\u003e\n\u003ctd\u003eMicro SD \u0026lt;= 32 GBUSB memory stick \u0026lt;= 32 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e10 Mbit\/s100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eElectronics and sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, function\u003c\/th\u003e\n\u003ctd\u003eDiagnosticsSwitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem parameter\u003c\/th\u003e\n\u003ctd\u003eFail-safe responseDiagnostic memorySystem start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eChannel alarms for undervoltageAnalog module process value representationUndervoltage diagnosticsChannel alarm bundling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eForce mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for outputs\u003c\/th\u003e\n\u003ctd\u003e512 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for inputs\u003c\/th\u003e\n\u003ctd\u003e512 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU data\u003c\/th\u003e\n\u003ctd\u003e512 MB RAMDual core 766 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eOperator unit CDSBCODESYS V3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional functions\u003c\/th\u003e\n\u003ctd\u003eCODESYS V3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eDIL switch for RUN\/STOPOptional: CDSB operating unitRotary switch for address setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcessing time\u003c\/th\u003e\n\u003ctd\u003eApprox. 200 Âµs\/1 k instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP address setting\u003c\/th\u003e\n\u003ctd\u003eVia CODESYSOptional: via CDSB operating unitDHCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction blocks\u003c\/th\u003e\n\u003ctd\u003eand othersCPX-E diagnostic statusCopying of CPX-E diagnostic traceRead CPX-E module diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e0.333333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlag\u003c\/th\u003e\n\u003ctd\u003e120 kB remanent dataCODESYS variable concept\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgramming software\u003c\/th\u003e\n\u003ctd\u003eCODESYS provided by Festo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgram memory\u003c\/th\u003e\n\u003ctd\u003e12 MB user program\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003eNon-condensing95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003ec UL us - Listed (OL)RCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e288 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantContains paint-wetting impairment substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767070830747,"sku":"4252742","price":2063.33,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4252742-1.jpg?v=1781399132"},{"product_id":"4252743","title":"CPX-E-CEC-M1-PN","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e75.9 mm x 124.3 mm x 82.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, protocol\u003c\/th\u003e\n\u003ctd\u003eModbusÂ® TCPEasyIPTCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage medium\u003c\/th\u003e\n\u003ctd\u003eMicro SD \u0026lt;= 32 GBUSB memory stick \u0026lt;= 32 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e10 Mbit\/s100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eElectronics and sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, function\u003c\/th\u003e\n\u003ctd\u003eSwitchDiagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem parameter\u003c\/th\u003e\n\u003ctd\u003eDiagnostic memorySystem startFail-safe response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003ePROFINET IO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eUndervoltage diagnosticsAnalog module process value representationChannel alarms for undervoltageChannel alarm bundling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eMaintenance requiredNetwork status, port 1Engineering port 2 network statusNetwork errorEtherCAT network statusNetwork status, engineering port 1System faultNetwork status, port 2Power supply for electronics\/sensorsRunForce modeLoad power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for outputs\u003c\/th\u003e\n\u003ctd\u003e512 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for inputs\u003c\/th\u003e\n\u003ctd\u003e512 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU data\u003c\/th\u003e\n\u003ctd\u003e512 MB RAMDual core 766 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eOperator unit CDSBGSDML fileCODESYS V3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional functions\u003c\/th\u003e\n\u003ctd\u003eCODESYS V3 with SoftMotion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eOptional: CDSB operating unitDIL switch for RUN\/STOP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcessing time\u003c\/th\u003e\n\u003ctd\u003eApprox. 200 Âµs\/1 k instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP address setting\u003c\/th\u003e\n\u003ctd\u003eVia CODESYSDHCPOptional: via CDSB operating unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction blocks\u003c\/th\u003e\n\u003ctd\u003eand othersRead CPX-E module diagnosticsCPX-E diagnostic statusCopying of CPX-E diagnostic trace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e0.333333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlag\u003c\/th\u003e\n\u003ctd\u003e120 kB remanent dataCODESYS variable concept\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgramming software\u003c\/th\u003e\n\u003ctd\u003eCODESYS provided by Festo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgram memory\u003c\/th\u003e\n\u003ctd\u003e12 MB user program\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003eNon-condensing95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003ec UL us - Listed (OL)RCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e288 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantContains paint-wetting impairment substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767071387803,"sku":"4252743","price":2740.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4252743-1.jpg?v=1781399134"},{"product_id":"4252744","title":"CPX-E-CEC-M1-EP","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e75.9 mm x 124.3 mm x 82.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEasyIPTCP\/IPModbusÂ® TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage medium\u003c\/th\u003e\n\u003ctd\u003eUSB memory stick \u0026lt;= 32 GBMicro SD \u0026lt;= 32 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, incoming\/forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s10 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eElectronics and sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUSB interface\u003c\/th\u003e\n\u003ctd\u003eUSB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, function\u003c\/th\u003e\n\u003ctd\u003eSwitchDiagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem parameter\u003c\/th\u003e\n\u003ctd\u003eDiagnostic memoryFail-safe responseSystem start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherNet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eChannel alarm bundlingAnalog module process value representationUndervoltage diagnosticsChannel alarms for undervoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection type\u003c\/th\u003e\n\u003ctd\u003e2x socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eForce mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface 2, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for outputs\u003c\/th\u003e\n\u003ctd\u003e512 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, max. address volume for inputs\u003c\/th\u003e\n\u003ctd\u003e512 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU data\u003c\/th\u003e\n\u003ctd\u003e512 MB RAMDual core 766 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eCODESYS V3Operator unit CDSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional functions\u003c\/th\u003e\n\u003ctd\u003eCODESYS V3 with SoftMotion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eRotary switch for address settingDIL switch for RUN\/STOPOptional: CDSB operating unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcessing time\u003c\/th\u003e\n\u003ctd\u003eApprox. 200 Âµs\/1 k instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP address setting\u003c\/th\u003e\n\u003ctd\u003eOptional: via CDSB operating unitVia CODESYSDHCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction blocks\u003c\/th\u003e\n\u003ctd\u003eand othersCopying of CPX-E diagnostic traceRead CPX-E module diagnosticsCPX-E diagnostic status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e0.333333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlag\u003c\/th\u003e\n\u003ctd\u003e120 kB remanent dataCODESYS variable concept\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgramming software\u003c\/th\u003e\n\u003ctd\u003eCODESYS provided by Festo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgram memory\u003c\/th\u003e\n\u003ctd\u003e12 MB user program\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003e95 %Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003ec UL us - Listed (OL)RCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e288 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantContains paint-wetting impairment substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767073419419,"sku":"4252744","price":2740.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4252744-1.jpg?v=1781399136"},{"product_id":"4827505","title":"CPX-E-1CI","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e18.9 mm x 76.6 mm x 124.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, function\u003c\/th\u003e\n\u003ctd\u003eDigital input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 15 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input, information on conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995843\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via bus\u003c\/th\u003e\n\u003ctd\u003eZero-pulse monitoringMeasuring system errorWire break monitoringSensor supply short circuit\/overloadParameter errorMisalignment monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995844\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eEncoder supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical input connection, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input, connection type\u003c\/th\u003e\n\u003ctd\u003e2x terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eMisalignment monitoringLower count limitUpper counting limitLoad valueZero-pulse monitoringPulses\/zero pulseLine break monitoringSignal type\/encoder typeSignal analysisInternal revision IDLatch signalLatch eventSpeed measurement integration timeDebounce time for digital inputsLatching response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChannel parameters\u003c\/th\u003e\n\u003ctd\u003eSignal extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eEncoder supply faultEncoder supply normal operationEncoder normal operationStatus per channelFaults per moduleEncoder error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input 2, function\u003c\/th\u003e\n\u003ctd\u003eCounter input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection input 2, connection type\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input 2, information on conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input 2, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995848\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection, input, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection, input 2, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input, conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection for input 2, conductor cross section\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of inputs\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput debounce time\u003c\/th\u003e\n\u003ctd\u003e0.1 ms3 ms0.02 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current of inputs per module\u003c\/th\u003e\n\u003ctd\u003e1.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channels\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSwitching level\u003c\/th\u003e\n\u003ctd\u003eSignal 1: \u0026gt;= 11 VSignal 0: \u0026lt;= 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003eNon-condensing95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003eRCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e88 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e2 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e12 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput characteristics\u003c\/th\u003e\n\u003ctd\u003eAs per IEC 61131-2, type 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput switching logic\u003c\/th\u003e\n\u003ctd\u003e3-wire sensors as per IEC 61131-2PNP (positive switching)2-wire sensors as per IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliantContains paint-wetting impairment substances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767111594139,"sku":"4827505","price":424.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/4827505-1.jpg?v=1781399573"},{"product_id":"5226780","title":"CPX-E-CEC-C1","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e42.2 mm x 125.8 mm x 76.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, protocol\u003c\/th\u003e\n\u003ctd\u003eTCP\/IPEasyIPModbusÂ® TCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e10 Mbit\/s100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eElectronics and sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, function\u003c\/th\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem parameter\u003c\/th\u003e\n\u003ctd\u003eDiagnostic memorySystem startFail-safe response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eAnalog module process value representationChannel alarm bundlingChannel alarms for undervoltageUndervoltage diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eEtherCAT network statusPower supply for electronics\/sensorsForce modeRunLoad power supplyNetwork status, engineering port 1System fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU data\u003c\/th\u003e\n\u003ctd\u003e512 MB RAMDual core 666 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eCODESYS V3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional functions\u003c\/th\u003e\n\u003ctd\u003eCODESYS V3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eDIL switch for RUN\/STOP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcessing time\u003c\/th\u003e\n\u003ctd\u003eApprox. 200 Âµs\/1 k instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP address setting\u003c\/th\u003e\n\u003ctd\u003eDHCPVia CODESYS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction blocks\u003c\/th\u003e\n\u003ctd\u003eCopying of CPX-E diagnostic traceand othersRead CPX-E module diagnosticsCPX-E diagnostic status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e0.333333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlag\u003c\/th\u003e\n\u003ctd\u003eCODESYS variable concept120 kB remanent data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgramming software\u003c\/th\u003e\n\u003ctd\u003eCODESYS provided by Festo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgram memory\u003c\/th\u003e\n\u003ctd\u003e12 MB user program\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003eNon-condensing95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003ec UL us - Listed (OL)RCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e145 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767122800795,"sku":"5226780","price":1049.16,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/5226780-1.jpg?v=1781399870"},{"product_id":"5266781","title":"CPX-E-CEC-M1","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions W x L x H\u003c\/th\u003e\n\u003ctd\u003e42.2 mm x 125.8 mm x 76.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, type of connection\u003c\/th\u003e\n\u003ctd\u003eTerminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, protocol\u003c\/th\u003e\n\u003ctd\u003eModbusÂ® TCPEasyIPTCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 - 60 Â°C for vertical installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eTypically 65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, function\u003c\/th\u003e\n\u003ctd\u003eBus connection, forwarding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s10 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, function\u003c\/th\u003e\n\u003ctd\u003eElectronics and sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, information on conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 - 2.5 mmÂ² for flexible conductors without cable end sleeves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, function\u003c\/th\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePermissible voltage fluctuations for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003eÂ± 25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSystem parameter\u003c\/th\u003e\n\u003ctd\u003eDiagnostic memoryFail-safe responseSystem start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, connection pattern\u003c\/th\u003e\n\u003ctd\u003e995789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, connection technology\u003c\/th\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, connection technology\u003c\/th\u003e\n\u003ctd\u003eSpring-loaded terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, protocol\u003c\/th\u003e\n\u003ctd\u003eEtherCAT Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 1 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModule parameters\u003c\/th\u003e\n\u003ctd\u003eChannel alarms for undervoltageChannel alarm bundlingAnalog module process value representationUndervoltage diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics via LED\u003c\/th\u003e\n\u003ctd\u003eRunPower supply for electronics\/sensorsSystem faultNetwork status, engineering port 1EtherCAT network statusForce modeLoad power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEthernet interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC for electronics\/sensors\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, number of poles\/wires\u003c\/th\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of modules\u003c\/th\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower supply, conductor diameter\u003c\/th\u003e\n\u003ctd\u003e0.2 mmÂ² ... 1.5 mmÂ²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWidth dimension\u003c\/th\u003e\n\u003ctd\u003e18.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eCPX-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCPU data\u003c\/th\u003e\n\u003ctd\u003e512 MB RAMDual core 666 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration support\u003c\/th\u003e\n\u003ctd\u003eCODESYS V3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdditional functions\u003c\/th\u003e\n\u003ctd\u003eCODESYS V3 with SoftMotion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eControl elements\u003c\/th\u003e\n\u003ctd\u003eDIL switch for RUN\/STOP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcessing time\u003c\/th\u003e\n\u003ctd\u003eApprox. 200 Âµs\/1 k instruction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIP address setting\u003c\/th\u003e\n\u003ctd\u003eDHCPVia CODESYS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction blocks\u003c\/th\u003e\n\u003ctd\u003eRead CPX-E module diagnosticsand othersCPX-E diagnostic statusCopying of CPX-E diagnostic trace\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply\u003c\/th\u003e\n\u003ctd\u003e0.333333333333333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlag\u003c\/th\u003e\n\u003ctd\u003eCODESYS variable concept120 kB remanent data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower failure buffering\u003c\/th\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgramming software\u003c\/th\u003e\n\u003ctd\u003eCODESYS provided by Festo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProgram memory\u003c\/th\u003e\n\u003ctd\u003e12 MB user program\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 Â°C ... 70 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative air humidity\u003c\/th\u003e\n\u003ctd\u003eNon-condensing95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection against direct and indirect contact\u003c\/th\u003e\n\u003ctd\u003ePELV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCertification\u003c\/th\u003e\n\u003ctd\u003ec UL us - Listed (OL)RCM compliance mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e145 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity outputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. address capacity inputs\u003c\/th\u003e\n\u003ctd\u003e64 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, galvanic isolation\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, transmission rate\u003c\/th\u003e\n\u003ctd\u003e100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFieldbus interface, type\u003c\/th\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith H-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767124242587,"sku":"5266781","price":1652.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/5266781-1.jpg?v=1781399940"}],"url":"https:\/\/festopneumatics.com\/collections\/cpx-e.oembed","provider":"Festo Pneumatics","version":"1.0","type":"link"}