{"title":"Adapter plates","description":null,"products":[{"product_id":"573613","title":"VABA-S6-1-X2-D","description":"pneumatic interface VABA-S6-1-X2-D Valve terminal interface=Type 44, VTSA, Diagnosis=- Undervoltage of valves, Max. number of valve positions=(* 16 with bistable valves, * 32 with monostable valves), LED displays=(* - 1 Group diagnosis, * - Channel status on valves), Parameters configuring=(* Failsafe per channel, * Forces per channel, * Idle mode per channel, * Module monitoring)\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve terminal interface\u003c\/th\u003e\n\u003ctd\u003eType 44, VTSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnosis\u003c\/th\u003e\n\u003ctd\u003e'- Undervoltage of valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of valve positions\u003c\/th\u003e\n\u003ctd\u003e16 with bistable valves32 with monostable valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED displays\u003c\/th\u003e\n\u003ctd\u003e'- 1 Group diagnosis- Channel status on valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameters configuring\u003c\/th\u003e\n\u003ctd\u003eFailsafe per channelForces per channelIdle mode per channelModule monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse protection per valve output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating voltage range DC\u003c\/th\u003e\n\u003ctd\u003e21.6 ... 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at operating voltage\u003c\/th\u003e\n\u003ctd\u003eTypically 15 mA (power supply for electronics)Typically 50 mA (load voltage supply for valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0,2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. resultant current per module\u003c\/th\u003e\n\u003ctd\u003e0.166666666666667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation channel – internal bus\u003c\/th\u003e\n\u003ctd\u003eYes, for additional power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance classification CRC\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48754606473371,"sku":"573613","price":383.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/573613-1.jpg?v=1781295296"},{"product_id":"550663","title":"VABA-S6-1-X2","description":"pneumatic interface VABA-S6-1-X2 For valve terminals VTSA and VTSA-F, functions as adapter between the parallel linking in the terminal and the serial linking (concatenation) of CPX. Valve terminal interface=Type 44, VTSA, Diagnosis=- Undervoltage of valves, Max. number of valve positions=(* 16 with bistable valves, * 32 with monostable valves), LED displays=(* - 1 Group diagnosis, * - Channel status on valves), Parameters configuring=(* Failsafe per channel, * Forces per channel, * Idle mode per channel, * Module monitoring)\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve terminal interface\u003c\/th\u003e\n\u003ctd\u003eType 44, VTSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnosis\u003c\/th\u003e\n\u003ctd\u003e'- Undervoltage of valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of valve positions\u003c\/th\u003e\n\u003ctd\u003e16 with bistable valves32 with monostable valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED displays\u003c\/th\u003e\n\u003ctd\u003e'- 1 Group diagnosis- Channel status on valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameters configuring\u003c\/th\u003e\n\u003ctd\u003eFailsafe per channelForces per channelIdle mode per channelModule monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse protection per valve output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating voltage range DC\u003c\/th\u003e\n\u003ctd\u003e21.6 ... 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at operating voltage\u003c\/th\u003e\n\u003ctd\u003eTypically 15 mA (power supply for electronics)Typically 50 mA (load voltage supply for valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0,2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. resultant current per module\u003c\/th\u003e\n\u003ctd\u003e0.166666666666667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation channel – internal bus\u003c\/th\u003e\n\u003ctd\u003eYes, for additional power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance classification CRC\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48757801975963,"sku":"550663","price":310.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/550663-1.jpg?v=1781304813"},{"product_id":"543416","title":"VABA-S6-1-X1","description":"pneumatic interface VABA-S6-1-X1 For valve terminals VTSA and VTSA-F, functions as adapter between the parallel linking in the terminal and the serial linking (concatenation) of CPX. Valve terminal interface=Type 44, VTSA, Diagnosis=- Undervoltage of valves, Max. number of valve positions=(* 16 with bistable valves, * 32 with monostable valves), LED displays=(* - 1 Group diagnosis, * - Channel status on valves), Parameters configuring=(* Failsafe per channel, * Forces per channel, * Idle mode per channel, * Module monitoring)\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eValve terminal interface\u003c\/th\u003e\n\u003ctd\u003eType 44, VTSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnosis\u003c\/th\u003e\n\u003ctd\u003e'- Undervoltage of valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. number of valve positions\u003c\/th\u003e\n\u003ctd\u003e16 with bistable valves32 with monostable valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED displays\u003c\/th\u003e\n\u003ctd\u003e'- 1 Group diagnosis- Channel status on valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameters configuring\u003c\/th\u003e\n\u003ctd\u003eFailsafe per channelForces per channelIdle mode per channelModule monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProtection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse protection per valve output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating voltage range DC\u003c\/th\u003e\n\u003ctd\u003e21.6 ... 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at operating voltage\u003c\/th\u003e\n\u003ctd\u003eTypically 15 mA (power supply for electronics)Typically 50 mA (load voltage supply for valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0,2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. resultant current per module\u003c\/th\u003e\n\u003ctd\u003e0.166666666666667\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation channel – internal bus\u003c\/th\u003e\n\u003ctd\u003eYes, for additional power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance classification CRC\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48759534977179,"sku":"543416","price":310.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/543416-1.jpg?v=1781310780"},{"product_id":"8082876","title":"VABA-S6-1-X2-CB","description":"","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767278416027,"sku":"8082876","price":313.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8082876-1.jpg?v=1781402515"},{"product_id":"8082877","title":"VABA-S6-1-X1-CB","description":"","brand":"Festo","offers":[{"title":"Default Title","offer_id":48767278448795,"sku":"8082877","price":313.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8082877-1.jpg?v=1781402517"},{"product_id":"8068240","title":"VABA-S6-1-X2-F1-CB","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVABA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValve manifold interface\u003c\/th\u003e\n\u003ctd\u003eType 44, VTSA-F-CB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics\u003c\/th\u003e\n\u003ctd\u003eWire break per valve coilShort circuit of pneumatic valvesUndervoltage of pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. no. of valve positions\u003c\/th\u003e\n\u003ctd\u003e12 for bistable pneumatic valves24 for monostable pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003e1 group diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization\u003c\/th\u003e\n\u003ctd\u003eFail-safe modes per channelForcing per channelIdle mode per channelModule monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per pneumatic valve output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC operating voltage range\u003c\/th\u003e\n\u003ctd\u003e21.6 V ... 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage\u003c\/th\u003e\n\u003ctd\u003eTyp. 110 mA for electronics with CPX-FVDA-P2Typ. 25 mA for pneumatic valves without CPX-FVDA-P2Typ. 45 mA for electronics without CPX-FVDA-P2Typ. 90 mA for pneumatic valves with CPX-FVDA-P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current per module\u003c\/th\u003e\n\u003ctd\u003e4.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eYes, when using an additional supply for the pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directiveAs per EU RoHS directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 °C ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e734 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical actuation\u003c\/th\u003e\n\u003ctd\u003eFieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection\u003c\/th\u003e\n\u003ctd\u003eVia CPX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of sub-base\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCover material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48768044236955,"sku":"8068240","price":902.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8068240-1.jpg?v=1781453943"},{"product_id":"8068241","title":"VABA-S6-1-X2-F2-CB","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, function\u003c\/th\u003e\n\u003ctd\u003eSafe digital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection output, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1 A-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical output connection, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eShock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVABA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValve manifold interface\u003c\/th\u003e\n\u003ctd\u003eType 44, VTSA-F-CB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics\u003c\/th\u003e\n\u003ctd\u003eWire break per valve coilShort circuit of pneumatic valvesUndervoltage of pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. no. of valve positions\u003c\/th\u003e\n\u003ctd\u003e12 for bistable pneumatic valves24 for monostable pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003e1 group diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization\u003c\/th\u003e\n\u003ctd\u003eFail-safe modes per channelForcing per channelIdle mode per channelModule monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per pneumatic valve output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC operating voltage range\u003c\/th\u003e\n\u003ctd\u003e21.6 V ... 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage\u003c\/th\u003e\n\u003ctd\u003eTyp. 110 mA for electronics with CPX-FVDA-P2Typ. 25 mA for pneumatic valves without CPX-FVDA-P2Typ. 45 mA for electronics without CPX-FVDA-P2Typ. 90 mA for pneumatic valves with CPX-FVDA-P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current per module\u003c\/th\u003e\n\u003ctd\u003e4.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eYes, when using an additional supply for the pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directiveAs per EU RoHS directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 °C ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e754 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical actuation\u003c\/th\u003e\n\u003ctd\u003eFieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection\u003c\/th\u003e\n\u003ctd\u003eVia CPX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of sub-base\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCover material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of screws\u003c\/th\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48768044466331,"sku":"8068241","price":902.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8068241-1.jpg?v=1781453945"},{"product_id":"8082878","title":"VABA-S6-1-X2-3V-CB","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVABA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValve manifold interface\u003c\/th\u003e\n\u003ctd\u003eType 44, VTSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics\u003c\/th\u003e\n\u003ctd\u003eWire break per valve coilShort circuit of pneumatic valvesUndervoltage of pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. no. of valve positions\u003c\/th\u003e\n\u003ctd\u003e12 for bistable pneumatic valves24 for monostable pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003e1 group diagnostics3 load supplyChannel status on pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization\u003c\/th\u003e\n\u003ctd\u003eFail-safe modes per channelForcing per channelIdle mode per channelModule monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per pneumatic valve output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC operating voltage range\u003c\/th\u003e\n\u003ctd\u003e21.6 V ... 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage\u003c\/th\u003e\n\u003ctd\u003etyp. 11 mA (electronics operating voltage supply)Typ. 45 mA (pneumatic valve load power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current per module\u003c\/th\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65NEMA 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 °C ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e580 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical actuation\u003c\/th\u003e\n\u003ctd\u003eFieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection\u003c\/th\u003e\n\u003ctd\u003e3x M12x1 A-coded5-pinPlugVia CPX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCover material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48768101744795,"sku":"8082878","price":333.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8082878-1.jpg?v=1781454258"},{"product_id":"8082879","title":"VABA-S6-1-X1-3V-CB","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVABA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eValve manifold interface\u003c\/th\u003e\n\u003ctd\u003eType 44, VTSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDiagnostics\u003c\/th\u003e\n\u003ctd\u003eWire break per valve coilShort circuit of pneumatic valvesUndervoltage of pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. no. of valve positions\u003c\/th\u003e\n\u003ctd\u003e12 for bistable pneumatic valves24 for monostable pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLED indicators\u003c\/th\u003e\n\u003ctd\u003e1 group diagnostics3 load supplyChannel status on pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eParameterization\u003c\/th\u003e\n\u003ctd\u003eFail-safe modes per channelForcing per channelIdle mode per channelModule monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per pneumatic valve output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC operating voltage range\u003c\/th\u003e\n\u003ctd\u003e21.6 V ... 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIntrinsic current consumption at nominal operating voltage\u003c\/th\u003e\n\u003ctd\u003etyp. 11 mA (electronics operating voltage supply)Typ. 45 mA (pneumatic valve load power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. residual current per module\u003c\/th\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDegree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65NEMA 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-5 °C ... 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e580 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical actuation\u003c\/th\u003e\n\u003ctd\u003eFieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical connection\u003c\/th\u003e\n\u003ctd\u003e3x M12x1 A-coded5-pinPlugVia CPX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCover material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48768101875867,"sku":"8082879","price":333.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8082879-1.jpg?v=1781454260"},{"product_id":"8098889","title":"VABA-B14-FL12-FL14","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eType code\u003c\/th\u003e\n\u003ctd\u003eVABA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting position\u003c\/th\u003e\n\u003ctd\u003eAny\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e1.5 bar ... 10 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating medium\u003c\/th\u003e\n\u003ctd\u003eCompressed air as per ISO 8573-1:2010 [7:-:-]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCorrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e2 - Moderate corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature of medium\u003c\/th\u003e\n\u003ctd\u003e-20 °C ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20 °C ... 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct weight\u003c\/th\u003e\n\u003ctd\u003e188 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eType of mounting\u003c\/th\u003e\n\u003ctd\u003eWith through-hole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 2\u003c\/th\u003e\n\u003ctd\u003eFlange 1\/2 with NAMUR port pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePneumatic connection 4\u003c\/th\u003e\n\u003ctd\u003eFlange 1\/4 with NAMUR port pattern\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNote on materials\u003c\/th\u003e\n\u003ctd\u003eContains paint-wetting impairment substancesRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaterial of sub-base\u003c\/th\u003e\n\u003ctd\u003eWrought aluminum alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48768303136923,"sku":"8098889","price":99.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8098889-1.jpg?v=1781455139"},{"product_id":"8152353","title":"VABA-S6-1-PT","description":"","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769077379227,"sku":"8152353","price":282.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8152353-1.jpg?v=1781458491"},{"product_id":"8152434","title":"VABA-S6-1-X2-F2-CB2-AL","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e Vibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Shock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Valve manifold interface\u003c\/th\u003e\n\u003ctd\u003eType 44, VTSA-F-CB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Diagnostics\u003c\/th\u003e\n\u003ctd\u003eWire break per valve coil Short circuit of pneumatic valves Undervoltage of pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. no. of valve positions\u003c\/th\u003e\n\u003ctd\u003e12 for bistable pneumatic valves 24 for monostable pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e LED indicators\u003c\/th\u003e\n\u003ctd\u003e1 group diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Parameterization\u003c\/th\u003e\n\u003ctd\u003eFail-safe modes per channel Forcing per channel Idle mode per channel Module monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per pneumatic valve output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e DC operating voltage range\u003c\/th\u003e\n\u003ctd\u003e 21.6 V ... 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Intrinsic current consumption at nominal operating voltage\u003c\/th\u003e\n\u003ctd\u003eTyp. 15 mA for valves without CPX-FVDA-P2 Typ. 25 mA for electronics with CPX-FVDA-P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. residual current per module\u003c\/th\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eYes, when using an additional supply for the pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e CE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive As per EU RoHS directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Corrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Storage temperature\u003c\/th\u003e\n\u003ctd\u003e -20 Â°C ... 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Ambient temperature\u003c\/th\u003e\n\u003ctd\u003e -5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Product weight\u003c\/th\u003e\n\u003ctd\u003e1596 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical actuation\u003c\/th\u003e\n\u003ctd\u003eFieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection output, function\u003c\/th\u003e\n\u003ctd\u003eSafe digital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection output, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection output, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1 A-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical output connection, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection valve, function\u003c\/th\u003e\n\u003ctd\u003ePower supply valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Pneumatic valve electrical connection, connection type\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical pneumatic valve connection, connection technology\u003c\/th\u003e\n\u003ctd\u003e7\/8\" round plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical pneumatic valve connection, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection\u003c\/th\u003e\n\u003ctd\u003eVia CPX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Note on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Material of sub-base\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Cover material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Seals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Material of screws\u003c\/th\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769100775579,"sku":"8152434","price":1610.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8152434-1.jpg?v=1781458576"},{"product_id":"8152435","title":"VABA-S6-1-X2-F1-CB2-AL","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e Vibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Shock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Valve manifold interface\u003c\/th\u003e\n\u003ctd\u003eType 44, VTSA-F-CB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Diagnostics\u003c\/th\u003e\n\u003ctd\u003eWire break per valve coil Short circuit of pneumatic valves Undervoltage of pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. no. of valve positions\u003c\/th\u003e\n\u003ctd\u003e12 for bistable pneumatic valves 24 for monostable pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e LED indicators\u003c\/th\u003e\n\u003ctd\u003e1 group diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Parameterization\u003c\/th\u003e\n\u003ctd\u003eFail-safe modes per channel Forcing per channel Idle mode per channel Module monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per pneumatic valve output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e DC operating voltage range\u003c\/th\u003e\n\u003ctd\u003e 21.6 V ... 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Intrinsic current consumption at nominal operating voltage\u003c\/th\u003e\n\u003ctd\u003eTyp. 15 mA for valves without CPX-FVDA-P2 Typ. 25 mA for electronics with CPX-FVDA-P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. residual current per module\u003c\/th\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eYes, when using an additional supply for the pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e CE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive As per EU RoHS directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Corrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Storage temperature\u003c\/th\u003e\n\u003ctd\u003e -20 Â°C ... 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Ambient temperature\u003c\/th\u003e\n\u003ctd\u003e -5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Product weight\u003c\/th\u003e\n\u003ctd\u003e1576 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical actuation\u003c\/th\u003e\n\u003ctd\u003eFieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection valve, function\u003c\/th\u003e\n\u003ctd\u003ePower supply valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Pneumatic valve electrical connection, connection type\u003c\/th\u003e\n\u003ctd\u003ePlug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical pneumatic valve connection, connection technology\u003c\/th\u003e\n\u003ctd\u003e7\/8\" round plug connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical pneumatic valve connection, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection\u003c\/th\u003e\n\u003ctd\u003eVia CPX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Note on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Material of sub-base\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Cover material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Seals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Material of screws\u003c\/th\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769100841115,"sku":"8152435","price":1610.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8152435-1.jpg?v=1781458578"},{"product_id":"8152436","title":"VABA-S6-1-X2-F2-CB-AL","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e Vibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Shock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Valve manifold interface\u003c\/th\u003e\n\u003ctd\u003eType 44, VTSA-F-CB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Diagnostics\u003c\/th\u003e\n\u003ctd\u003eWire break per valve coil Short circuit of pneumatic valves Undervoltage of pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. no. of valve positions\u003c\/th\u003e\n\u003ctd\u003e12 for bistable pneumatic valves 24 for monostable pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e LED indicators\u003c\/th\u003e\n\u003ctd\u003e1 group diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Parameterization\u003c\/th\u003e\n\u003ctd\u003eFail-safe modes per channel Forcing per channel Idle mode per channel Module monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per pneumatic valve output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e DC operating voltage range\u003c\/th\u003e\n\u003ctd\u003e 21.6 V ... 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Intrinsic current consumption at nominal operating voltage\u003c\/th\u003e\n\u003ctd\u003eTyp. 15 mA for valves without CPX-FVDA-P2 Typ. 25 mA for electronics with CPX-FVDA-P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. residual current per module\u003c\/th\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eYes, when using an additional supply for the pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e CE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive As per EU RoHS directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Corrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Storage temperature\u003c\/th\u003e\n\u003ctd\u003e -20 Â°C ... 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Ambient temperature\u003c\/th\u003e\n\u003ctd\u003e -5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Product weight\u003c\/th\u003e\n\u003ctd\u003e1562 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical actuation\u003c\/th\u003e\n\u003ctd\u003eFieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection output, function\u003c\/th\u003e\n\u003ctd\u003eSafe digital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection output, connection type\u003c\/th\u003e\n\u003ctd\u003eSocket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection output, connection technology\u003c\/th\u003e\n\u003ctd\u003eM12x1 A-coded as per EN 61076-2-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical output connection, number of pins\/wires\u003c\/th\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection\u003c\/th\u003e\n\u003ctd\u003eVia CPX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Note on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Material of sub-base\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Cover material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Seals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Material of screws\u003c\/th\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769101496475,"sku":"8152436","price":1610.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8152436-1.jpg?v=1781458581"},{"product_id":"8152437","title":"VABA-S6-1-X2-F1-CB-AL","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e Vibration resistance\u003c\/th\u003e\n\u003ctd\u003eTransport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Shock resistance\u003c\/th\u003e\n\u003ctd\u003eShock test with severity level 2 as per FN 942017-5 and EN 60068-2-27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Valve manifold interface\u003c\/th\u003e\n\u003ctd\u003eType 44, VTSA-F-CB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Diagnostics\u003c\/th\u003e\n\u003ctd\u003eWire break per valve coil Short circuit of pneumatic valves Undervoltage of pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. no. of valve positions\u003c\/th\u003e\n\u003ctd\u003e12 for bistable pneumatic valves 24 for monostable pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e LED indicators\u003c\/th\u003e\n\u003ctd\u003e1 group diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Parameterization\u003c\/th\u003e\n\u003ctd\u003eFail-safe modes per channel Forcing per channel Idle mode per channel Module monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per pneumatic valve output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e DC operating voltage range\u003c\/th\u003e\n\u003ctd\u003e 21.6 V ... 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Intrinsic current consumption at nominal operating voltage\u003c\/th\u003e\n\u003ctd\u003eTyp. 15 mA for valves without CPX-FVDA-P2 Typ. 25 mA for electronics with CPX-FVDA-P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. residual current per module\u003c\/th\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eYes, when using an additional supply for the pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e CE marking (see declaration of conformity)\u003c\/th\u003e\n\u003ctd\u003eAs per EU EMC directive As per EU RoHS directive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Corrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Storage temperature\u003c\/th\u003e\n\u003ctd\u003e -20 Â°C ... 60 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Ambient temperature\u003c\/th\u003e\n\u003ctd\u003e -5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Product weight\u003c\/th\u003e\n\u003ctd\u003e1542 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical actuation\u003c\/th\u003e\n\u003ctd\u003eFieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection\u003c\/th\u003e\n\u003ctd\u003eVia CPX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Note on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Material of sub-base\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Cover material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Seals material\u003c\/th\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Material of screws\u003c\/th\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769101922459,"sku":"8152437","price":1610.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8152437-1.jpg?v=1781458583"},{"product_id":"8152438","title":"VABA-S6-1-X2-3V-CB-AL","description":"\u003ctable class=\"product-attributes-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e Valve manifold interface\u003c\/th\u003e\n\u003ctd\u003eType 44, VTSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Diagnostics\u003c\/th\u003e\n\u003ctd\u003eWire break per valve coil Short circuit of pneumatic valves Undervoltage of pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. no. of valve positions\u003c\/th\u003e\n\u003ctd\u003e12 for bistable pneumatic valves 24 for monostable pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e LED indicators\u003c\/th\u003e\n\u003ctd\u003e1 group diagnostics 3 load supply Channel status on pneumatic valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Parameterization\u003c\/th\u003e\n\u003ctd\u003eFail-safe modes per channel Forcing per channel Idle mode per channel Module monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Fuse protection (short circuit)\u003c\/th\u003e\n\u003ctd\u003eInternal electronic fuse per pneumatic valve output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e DC operating voltage range\u003c\/th\u003e\n\u003ctd\u003e 21.6 V ... 26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Intrinsic current consumption at nominal operating voltage\u003c\/th\u003e\n\u003ctd\u003etyp. 11 mA (electronics operating voltage supply) Typ. 45 mA (pneumatic valve load power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. power supply per channel\u003c\/th\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Max. residual current per module\u003c\/th\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Nominal operating voltage DC\u003c\/th\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical isolation between channel and internal bus\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Corrosion resistance class (CRC)\u003c\/th\u003e\n\u003ctd\u003e0 - No corrosion stress\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e LABS conformity\u003c\/th\u003e\n\u003ctd\u003eVDMA24364-B1\/B2-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Degree of protection\u003c\/th\u003e\n\u003ctd\u003eIP65 NEMA 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Ambient temperature\u003c\/th\u003e\n\u003ctd\u003e -5 Â°C ... 50 Â°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Product weight\u003c\/th\u003e\n\u003ctd\u003e1388 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical actuation\u003c\/th\u003e\n\u003ctd\u003eFieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Electrical connection\u003c\/th\u003e\n\u003ctd\u003e3x M12x1 A-coded 5-pin Plug Via CPX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Note on materials\u003c\/th\u003e\n\u003ctd\u003eRoHS-compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Cover material\u003c\/th\u003e\n\u003ctd\u003ePA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e Housing material\u003c\/th\u003e\n\u003ctd\u003eDie-cast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Festo","offers":[{"title":"Default Title","offer_id":48769102086299,"sku":"8152438","price":1042.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/files\/8152438-1.jpg?v=1781458584"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0768\/2578\/8571\/collections\/8152438-1.jpg?v=1781720788","url":"https:\/\/festopneumatics.com\/collections\/accessories-for-pneumatic-valves-adapter-plates.oembed","provider":"Festo Pneumatics","version":"1.0","type":"link"}